Inspection
Inspection Details
Equipment ID
6869
6869
Inspection Date
12/9/2021
12/9/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jeffrey Krug
Jeffrey Krug
Mechanic Name
Kurt Warttig
Kurt Warttig
Relief Valve Pressure
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
24
24
External ID
f0b4b825-6d74-4975-a4db-b0c3bf4a4f3c
f0b4b825-6d74-4975-a4db-b0c3bf4a4f3c
Location
Wellington Arms I
11333 Sugar Pine Dr, Florissant, MO
Phone: (314) 831-3200
11333 Sugar Pine Dr, Florissant, MO
Phone: (314) 831-3200
Owner
Attn: New Wellington Associates
New Wellington Associates
63 Centre St, Newton, MA 02459
Phone: (000) 000-0000
New Wellington Associates
63 Centre St, Newton, MA 02459
Phone: (000) 000-0000
Billing
Attn: Doug Bogaski
Wellington Arms 1
11333 Sugar Pine Dr, Florissant, MO 63033
Phone: (314) 831-3200
Email: dbogaski@wingatecompanies.com
Wellington Arms 1
11333 Sugar Pine Dr, Florissant, MO 63033
Phone: (314) 831-3200
Email: dbogaski@wingatecompanies.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display the current state operating certificate. | 11/16/2025 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | The cab lighting shall be properly guarded to prevent accidental contact or breakage. | 11/16/2025 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.7 Firefighter' Service Operating Procedures | No | No | Provide Firemans Return Phase 1 instructions in the lobby near the key switch. | 11/16/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit shall be kept clean. | 11/16/2025 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1001.2(a)(17) | Yes | No | Emergency power shall be tested. | 8/16/2021 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | The pit light switch shall be accessible from the hoistway door. | 11/16/2025 |
| A17.1-1996 : Elevators | 1.14 - Ventilation | 1001.2(a)(14) | No | No | The cab ventilation fan shall be operational. | 11/16/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | -Emergency Phone in car fails to establish two-way communication | 11/15/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | No | 210.8 The brake switches are not working. The elevator will run regardless of the position of the brake. | 12/6/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | Yes | 8.6.4.6 The main brake is not opening when the elevator runs. The elevator is running through the brake | 12/6/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | Yes | No | There are holes appearing in the platform flooring from excessive corrosion. Repair platform flooring with appropriate fire rated material. | 12/6/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The Emergency Phone in the car fails to establish two-way communication. | 11/16/2025 |