Inspection
Inspection Details
Equipment ID
18414
18414
Inspection Date
8/15/2018
8/15/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Jeremiah Dugger
Jeremiah Dugger
Relief Valve Pressure
Slide
Governor Rope Pull
NA / NA
NA / NA
Door Closing Force
28
28
External ID
102246fd-a08b-4dee-a1ce-a5704c8fefd4
102246fd-a08b-4dee-a1ce-a5704c8fefd4
Location
Monarch Cove Condos
183 MONARCH CV, LAKE OZARK, MO
183 MONARCH CV, LAKE OZARK, MO
Owner
Monarch Cove Condo Owners Association
PO BOX 189, OSAGE BEACH, MO 65065-0189
PO BOX 189, OSAGE BEACH, MO 65065-0189
Billing
Attn: PMP
PO BOX 189, OSAGE BEACH, MO 65065-0189
PO BOX 189, OSAGE BEACH, MO 65065-0189
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 8.11.2.3.1 | Yes | Yes | 5 year safety test due | 9/17/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.3 - Operating control devices | 2.26.1.1 | No | No | Car push buttons not legible | 2/26/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | No | No | Equipment room door knob needs to be self locking | 5/6/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | No | No | door not self locking | 5/6/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | maintenance records | 5/6/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | machine room door not self locking | 5/6/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | PHONE NOT WORKING | 7/1/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | NEEDS CURRENT TEST TAG | 5/6/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | MACHINE ROOM DOOR MUST BE SELF LOCKING | 5/6/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | NEEDS CURRENT TEST TAG | 5/6/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | MACHINE ROOM DOOR MUST BE SELF LOCKING | 5/6/2026 |