Inspection
Inspection Details
Equipment ID
21868
21868
Inspection Date
12/13/2021
12/13/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Jerry Reasoner
Jerry Reasoner
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
22
22
External ID
c069ce73-328b-4f8a-ae30-0245ea8a0803
c069ce73-328b-4f8a-ae30-0245ea8a0803
Location
Holiday Inn Express
3600 VILLAGE DR, SAINT JOSEPH, MO
Phone: (816) 232-2500
3600 VILLAGE DR, SAINT JOSEPH, MO
Phone: (816) 232-2500
Owner
Attn: Scott Ehrhardt
Ehrhardts Jefferson City, LLC
2 Melgrove Ln, Hannibal, MO 63401
Phone: (816) 232-2500
Alt Phone: (573) 795-5642
Email: scottehrhardt@gmail.com
Ehrhardts Jefferson City, LLC
2 Melgrove Ln, Hannibal, MO 63401
Phone: (816) 232-2500
Alt Phone: (573) 795-5642
Email: scottehrhardt@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Post firefighter operating instructions next to hall fire keyswitch | 3/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Remove Phase 2 firefighter instructions next to hall fire keyswitch. Post Phase 1 firefighter instructions next to hall fire keyswitch. | 9/29/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters Emergency Operation: Monthly Testing | No | No | Test and log firefighter operation monthly | 9/29/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Wiring diagrams can not be stored on top of elevator. | 9/29/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(b)(1) | No | No | Provide written documentation on unique testing procedures, such as ascending car protection and unintended motion, and keep permanently on site. | 12/23/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | Emergency light does not illuminate | 3/15/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing | 2.14.1.7 Railing and Equipment on Top of Cars | No | No | Install top of car handrail where distance from hoistway wall to the edge of the car top enclosure exceeds 12 inches | 3/15/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(b)(1) | No | No | Written specific procedures for testing (i.e., ascending car protection , and unintended movement) need to be kept on site. | 3/15/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4 Instructions for Locating Maintenance Records | No | No | Instructions for obtaining maintenance records need to be listed on the controller, or at the means necessary for test. | 3/15/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(a)(1) | No | No | No written maintenance records on site for 2022 | 3/15/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(c)(3) | No | No | Install periodic test tag for annual test in 2022, and 5 yeat test performed Jan 2020 | 3/15/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Repair top of car blocking device. The blocking device does not engage with the rail mounted holding bracket | 12/20/2023 |