Inspection
Inspection Details
Equipment ID
19189
19189
Inspection Date
5/22/2018
5/22/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
John Ryan
John Ryan
Mechanic Name
Kenneth Gustavson
Kenneth Gustavson
Relief Valve Pressure
Slide
Governor Rope Pull
N/A
N/A
Door Closing Force
26
26
External ID
c0998fdc-494a-4804-8b8d-2fa9665c5085
c0998fdc-494a-4804-8b8d-2fa9665c5085
Location
Montclair on the Park
18 S KINGSHIGHWAY BLVD, SAINT LOUIS, MO
18 S KINGSHIGHWAY BLVD, SAINT LOUIS, MO
Owner
Frontenance Associates LLC
40 N KINGSHIGHWAY BLVD STE 1, SAINT LOUIS, MO 63108-1355
40 N KINGSHIGHWAY BLVD STE 1, SAINT LOUIS, MO 63108-1355
Billing
Attn: Frontenance Associates LLC c/o Montclair on the Park
40 N KINGSHIGHWAY BLVD STE 1, SAINT LOUIS, MO 63108-1355
40 N KINGSHIGHWAY BLVD STE 1, SAINT LOUIS, MO 63108-1355
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 8.11.2.1.3(cc) | Suspension ropes shall have a rope data tag installed. | 5/1/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 8.11.2.1.2(d) | Remove all non-elevator related equipment from the machine room. | 8/16/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(e) (Re-Inspection) | Remove the excessive trash in the elevator machine room. | 8/16/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.8 - Hoistway enclosure | 8.11.2.1.4(h) | Provide lobby warning placards in all lobbies. | 8/16/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | Provide feeder location on main line and 110v disconnects. | 8/16/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 8.11.2.1.3(z) | Provide governor rope cable data tag. | 8/16/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | Provide a max counterweight runby sign in the pit. | 8/16/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | Feeder locations shall be marked on main disconnects and car lighting branch circuit disconnects. | 9/24/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.2.1 | Machinery and equipment not used in conjunction with the function or use of the elevator shall be removed from the elevator machine room. | 9/24/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | The penetrations in the hoistway overhead shall be sealed. | 9/24/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | A sign shall be posted adjacent to hall call fixtures instructing occupants not to use the elevator in case of fire. The sign shall include only the wording and graphics shown in Fig. 2.27.9 of A17.1-2005. | 9/24/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 5/14/2021 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | The emergency power fixture at the egress floor for this car shall be removed. This car does not operate under emergency power. | 5/14/2021 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | x | The in car emergency lighting shall be operational. | 5/17/2021 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The in car emergency bell shall be operational. | 5/17/2021 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | An up-to-date operating certificate is required in the machine room. | 5/18/2023 |