Inspection
Inspection Details
Equipment ID
6773
6773
Inspection Date
7/25/2018
7/25/2018
Inspection Type
Reinspection
Reinspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Relief Valve Pressure
480
480
Slide
Governor Rope Pull
Door Closing Force
NA
NA
External ID
f32223da-c80f-47ea-8a52-ab0a8a96ca44
f32223da-c80f-47ea-8a52-ab0a8a96ca44
Location
Lindell Plaza Apts
4300 LINDELL BLVD, SAINT LOUIS, MO
4300 LINDELL BLVD, SAINT LOUIS, MO
Owner
Whitangeles, LLP
4300 LINDELL BLVD, SAINT LOUIS, MO 63108-2724
4300 LINDELL BLVD, SAINT LOUIS, MO 63108-2724
Billing
Attn: WHITEANGELES LLP
1100 WOODCHASE LN, CHESTERFIELD, MO 63017-9748
1100 WOODCHASE LN, CHESTERFIELD, MO 63017-9748
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | x | Need to test FEO Phase I | 5/3/2018 | |
| conversion | conversion | n/a | Cab Ceiling lights shall be guarded. | 7/12/2021 | ||
| conversion | conversion | conversion - reinspect | x | Emergency light, bell and phone shall work. | 5/3/2018 | |
| conversion | conversion | conversion - reinspect | x | Car recalls during phase 1 operation ; however, light creen not bypassed and cab fire service buzzer inoperative, repair | 7/25/2018 | |
| conversion | conversion | conversion - reinspect | x | Guarded cab lighting | 7/25/2018 | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Replace ceiling tiles in car. | 7/12/2021 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Alarm bell inoperable and shall be repaired or replaced. | 3/19/2025 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Repair or replace door open and close buttons inside he elevator. | 2/28/2025 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Auxiliary lighting is inoperable and shall be repaired. | 2/27/2025 | ||
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7 | Auxiliary light is inoperable | |||
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency alarm inoperable. Re-inspection required | ||
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7 | The cab ceiling is of the open egg-crate type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. It is missing a ceiling panel, ceiling needs to be repaired. |