Inspection
Inspection Details
Equipment ID
15158
15158
Inspection Date
1/13/2022
1/13/2022
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Brenton Lane
Brenton Lane
Relief Valve Pressure
Slide
TBD
TBD
Governor Rope Pull
100/410
100/410
Door Closing Force
TBD
TBD
External ID
ea1e5918-489b-40bf-80d7-f8808acf5bd2
ea1e5918-489b-40bf-80d7-f8808acf5bd2
Location
SoHo Towers
5340 DELMAR BLVD, SAINT LOUIS, MO
Phone: (314) 367-7646
5340 DELMAR BLVD, SAINT LOUIS, MO
Phone: (314) 367-7646
Owner
Attn: Helix
Helix Realty Inc
5340 DELMAR BLVD APT 104, SAINT LOUIS, MO 63112
Phone: (314) 367-7646
Email: helixrealty@gmail.com
Helix Realty Inc
5340 DELMAR BLVD APT 104, SAINT LOUIS, MO 63112
Phone: (314) 367-7646
Email: helixrealty@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Wind up car safety rope shall be made of a non-corrosive material. | 12/4/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | In cab emergency telephone shall work. | 1/24/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | The hoist motor and motor generator sets shall have junction box covers in place. | 2/1/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Hoistway junction box at 6th floor shall have a cover. | 2/1/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | The safety rope shall be made of a non-corrosive material. | 1/18/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Unable to complete the annual inspection and category 5 test. The following items shall be tested to complete the inspection: Testing of emergency light, alarm, and bell with 110v removed, door pressure, slide, and oil buffer testing. | 1/18/2022 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Fire service not operating correctly. Elevator Red Tagged. | 4/29/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The 2024 annual inspection still needs to be completed. All testing items remain. | 4/29/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Fire service has been tested and red tag removed. The 2024 annual still needs to be completed. | 6/17/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm bell is not functional. | 7/18/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Auxiliary lighting is not functional. | 7/18/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Fire service panel at first floor is showing "trouble" error but smoke detectors are powered. Panel shall be repaired within 14 days or both elevators may be removed from service. | 7/18/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Hoist motors and generators shall have junction box covers in place. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | A current ABC fire extinguisher shall be provided in the machine room | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Broken windows in machine room shall be repaired. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self-closing & self-locking and open from the interior without the use of a key. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Yes | No | Stairs to machine room are deteriorated and handrail is loose and a section at the landing is completely missing, creating a fall hazard. Repair/replace as needed to create a safe condition. | 7/18/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current operating certificate shall be posted in the machine room in a non-combustible frame with a clear protective plate over it. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Fire service and door pressure shall be tested after SOS switch repaired to finish inspection. | 7/18/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Safety operator (SOS) broke during testing and needs to be repaired. | 7/18/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | Yes | Fire service panel at first floor is showing "trouble" error but smoke detectors are powered. Fire panel is completely non-functioning at this time. Elevator Red Tagged | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | Yes | Safety operator (SOS) broke during testing and needs to be repaired. Elevator Red Tagged. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm bell is not functional. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Auxiliary lighting is not functional. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Yes | No | Stairs to machine room are deteriorated and handrail is loose and a section at the landing is completely missing, creating a fall hazard. Repair/replace as needed to create a safe condition. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Fire service and door pressure shall be tested after SOS switch repaired to finish inspection. |