Inspection
Inspection Details
Equipment ID
16827
16827
Inspection Date
1/21/2022
1/21/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
18
18
External ID
7a4e0c76-887d-4710-a119-87787ab5f503
7a4e0c76-887d-4710-a119-87787ab5f503
Location
Interiors Unlimited
2149 SCHUETZ RD, SAINT LOUIS, MO
Phone: (314) 222-4060
2149 SCHUETZ RD, SAINT LOUIS, MO
Phone: (314) 222-4060
Owner
Attn: Lisa Lagermann
The Sherwin-Williams Co.
2145 SCHUETZ RD, Ste 200, SAINT LOUIS, MO 63146
Phone: (314) 997-3706
Fax: (314) 997-1603
Email: lisa.a.lagermann@sherwin.com
The Sherwin-Williams Co.
2145 SCHUETZ RD, Ste 200, SAINT LOUIS, MO 63146
Phone: (314) 997-3706
Fax: (314) 997-1603
Email: lisa.a.lagermann@sherwin.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | In car emergency bell shall work. | 6/28/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The in car emergency bell and light shall be operational. | 2/12/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean and dry. | 5/21/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. | 2/28/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Top floor door pickup roller shall be replaced. | 5/22/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Water on pit floor shall be removed. The pit shall be kept clean and dry. | 5/22/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher is expired. An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. | 5/22/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | A code data plate shall be provided on the machine. | 5/22/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | All pits shall be kept dry, clean and free of equipment or materials not relating to the operation of the elevator. | 5/9/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit has approximately 12" of water. Pit shall be kept dry, remvove rust from pit equipment, repair/replace as needed, apply rust prevention treatment to all pit steel, investigate/repair water leak. | |
| MO Minimum : Elevators | (I) - Pits | (I)2 | No | No | Pit sump pump is not working. Repair/replace as needed. | |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light shall work. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | All cab lighting lamps shall work. 1 of 2 lamps not working. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Machine room walls covered in mold up to about 3' above the floor. Clean/replace as needed. |