Inspection
Inspection Details
Equipment ID
13255
13255
Inspection Date
1/27/2022
1/27/2022
Inspection Type
Alteration
Alteration
Inspector Name
Conde (Cache) Kinsella
Conde (Cache) Kinsella
Mechanic Name
Zachary Thieme
Zachary Thieme
Relief Valve Pressure
410
410
Slide
Governor Rope Pull
Door Closing Force
N/A
N/A
External ID
c1f8647e-0da9-4958-b63b-3313a9aafb5f
c1f8647e-0da9-4958-b63b-3313a9aafb5f
Location
Comfort Inn Westport
12031 LACKLAND RD, SAINT LOUIS, MO
Phone: (314) 853-0576
12031 LACKLAND RD, SAINT LOUIS, MO
Phone: (314) 853-0576
Owner
Jerry Jariwala
12031 LACKLAND RD, SAINT LOUIS, MO 63146-4001
12031 LACKLAND RD, SAINT LOUIS, MO 63146-4001
Billing
Attn: Comfort Inn Westport
12031 LACKLAND RD, SAINT LOUIS, MO 63146-4001
12031 LACKLAND RD, SAINT LOUIS, MO 63146-4001
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Make emergency light operational. | 6/1/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Make emergency bell operational when 110V source is removed. | 6/18/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 8.6.5.8 - Confirm the hydraulic jack is code compliant and not a single bottom type or apply for a variance extension. | 6/1/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | The in car emergency light shall be operational. | 6/1/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | In car emergency bell shall be operational when 110v source is removed. | 5/26/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Confirm the hydraulic jack in code compliant and not a single bottom type, or apply for a variance exception. Provide on-site documentation of jack type. | 5/26/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be posted in the elevator machine room. | 6/1/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. | 9/14/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | A record of findings for firefighters' service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be available on-site. | 9/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 9/14/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | The disconnect located in the machine room shall be provided with a sign to identify the location of the supply side overcurrent protective device. | 9/14/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean the pit of dirt, debris, and oil. | 9/14/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | A pit ladder shall be provided. | 9/14/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.8 Safety Bulkhead | Yes | No | Need to determine if this unit is a single bottom jack. If it is determined to be a single bottom jack, corrective measures shall be taken. It unit is double bottom type, verification documentation shall be kept in the machine room. | 8/17/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.36 - Hydraulic Cylinders | 8.6.5.5.2 Collection of Oil Leakage | No | No | The hydraulic tank drip pan has an excessive amount of oil, it shall be cleaned. | 9/14/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 9/14/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | Pit ladder shall extend no less than 30" above pit access door sill. | 9/13/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light switch shall be accessible from pit access door. | 9/13/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | The means to restrict opening of the car door shall be operational. | 10/9/2024 |