Inspection
Inspection Details
Equipment ID
22183
22183
Inspection Date
1/25/2022
1/25/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Ledden
Michael Ledden
Mechanic Name
Charles Sheriff
Charles Sheriff
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
056c1491-0d0e-440f-8e0f-bef4cb2fed9b
056c1491-0d0e-440f-8e0f-bef4cb2fed9b
Location
Buick Mine/ Mill
270 Forest Rd 2231, Boss, MO
Phone: (573) 626-4855
270 Forest Rd 2231, Boss, MO
Phone: (573) 626-4855
Owner
Attn: Stacy Jones
The Doe Run Co
PO Box 500, Viburnum, MO 65566
Phone: (573) 626-2063
Email: srjones@doerun.com
The Doe Run Co
PO Box 500, Viburnum, MO 65566
Phone: (573) 626-2063
Email: srjones@doerun.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Pit must be enclosed with solid material. | 4/30/2020 |
| conversion | conversion | n/a | No | No | Must enclose intire hoistway. | 4/30/2020 |
| conversion | conversion | n/a | No | No | All landings must be enclosed with solid material to a height of 8'. | 4/30/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 12/4/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The emergency light and alarm shall be operational and shall be equipped with a 4 hour battery back-up. | 7/11/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Brake coil shall not be fed off hoist motor circuit. It shall have it's own circuit with two contacts. | 1/5/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Yes | No | Rope tags and code data tag required. | 1/5/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Unit left out of service. Floor stops need to be adjusted. | 1/5/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No MCP provided due to no maintenance contract. | 12/4/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | Yes | Unit failed 125% test. Red-tag issued. | 3/7/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | There is no MCP due to no maintenance contract. | 12/4/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The in-car alarm does not work. | 3/7/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The remainder of the annual and category 5 test shall be completed. Inspection stopped due to red tag. | 3/7/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The in-car alarm does not work. Take corrective action and re-test. | 1/6/2026 |