Inspection
Inspection Details
Equipment ID
14520
14520
Inspection Date
2/10/2022
2/10/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
6b15d9f8-e7b6-4616-b6e6-135b152760ad
6b15d9f8-e7b6-4616-b6e6-135b152760ad
Location
AT & T- Parking Garage
1126 Pine St, St. Louis, MO
Phone: (314) 235-9992
1126 Pine St, St. Louis, MO
Phone: (314) 235-9992
Owner
Attn: AT&T - Parking Garage
AT&T - Parking Garage
1126 Pine St, St. Louis, MO 63101
Phone: (314) 235-9992
AT&T - Parking Garage
1126 Pine St, St. Louis, MO 63101
Phone: (314) 235-9992
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | x | Emergency phone not working. | 2/26/2019 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Replace door pick-up rollers on floors 2 & 5 | 11/4/2025 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Replace missing car door guide shoe. | 11/4/2025 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | Replace loose hoistway door guide shoe. | 11/4/2025 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Repair inoperative phone. | 3/11/2020 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not work. | 3/26/2021 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No maintenance control program available in machine room. | 11/4/2025 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display current operating certificate in machine room. | 11/4/2025 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | Replace missing pickup rollers on 5th floor hoistway door | 11/4/2025 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current copy of the state operating certificate shall be displayed in the elevator machine room | 11/4/2025 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Phone in the elevator cab does not work, Re-inspection required | 1/27/2023 | |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | Replace missing pickup rollers on 5th floor hoistway door | 11/4/2025 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Phone in elevator cab does not work. Repair or replace | 3/1/2024 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Repair inoperative emergency phone | 9/13/2024 | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Phone not working. | 2/10/2025 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide current year tested fire extinguisher in the elevator machine room. Replace CO2 fe with ABC. |