Inspection
Inspection Details
Equipment ID
5768
5768
Inspection Date
2/10/2022
2/10/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
490
490
Slide
Governor Rope Pull
Door Closing Force
23
23
External ID
48fb6ebd-daae-4ec1-a6f8-1ed917ae3a59
48fb6ebd-daae-4ec1-a6f8-1ed917ae3a59
Location
US Bank
10 N Hanley Rd, Clayton, MO
Phone: (314) 505-8110
10 N Hanley Rd, Clayton, MO
Phone: (314) 505-8110
Owner
US Bank
10 N HANLEY RD, CLAYTON, MO 63105-3426
10 N HANLEY RD, CLAYTON, MO 63105-3426
Billing
Attn: US Bank
6701 N ILLINOIS ST, FAIRVIEW HEIGHTS, IL 62208-2019
6701 N ILLINOIS ST, FAIRVIEW HEIGHTS, IL 62208-2019
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | The pit depth exceeds 4 feet and there is no pit ladder provided for accessing the pit. Provide a proper, code-compliant pit ladder with handgrips extending 30 inches above the access floor for safe entry into the pit. The elevator hoistway may not be wide enough to install a pit ladder; a variance may need to be applied for. | |||
| conversion | conversion | n/a | The gate switch on the elevator car door shall be adjusted so that when the door is in the closed position, the gap between the leading edge of the door and the strike jamb is no more than 2 inches. | |||
| conversion | conversion | n/a | The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor. | |||
| conversion | conversion | n/a | The sump pump hole in the pit shall be provided with a noncombustible cover that is flush with the pit floor. There is currently no cover provided. | |||
| conversion | conversion | n/a | The normal limit switch in the pit shall be adjusted to activate before the elevator touches the buffer springs. | |||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | The pit depth exceeds 4 feet and there is no pit ladder provided for accessing the pit. Provide a proper, code-compliant pit ladder with handgrips extending 30 inches above the access floor for safe entry into the pit. The elevator hoistway may not be wide enough to install a pit ladder; a variance may need to be applied for. | |||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | The pit depth exceeds 4 feet and there is no pit ladder provided for accessing the pit. Provide a proper, code-compliant pit ladder with handgrips extending 30 inches above the access floor for safe entry into the pit. The elevator hoistway may not be wide enough to install a pit ladder; a variance may need to be applied for. | |||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the elevator machine room | |||
| A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | x | OSV is not sealed and needs full load test and tripping speed checked. Re-inspection required | 12/13/2022 | |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Elevator pit light does not work. The fixture switch shall be provided and accessible from the pit access door. | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the machine room | |||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light does not work. | |||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Elevator pit light does not work. The fixture switch shall be provided and accessible from the bottom landing hoistway door. | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the machine room |