Inspection
Inspection Details
Equipment ID
15006
15006
Inspection Date
9/14/2017
9/14/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Relief Valve Pressure
400
400
Slide
Governor Rope Pull
Door Closing Force
28
28
External ID
Location
Adams Elementary
1311 Tower Grove Ave, St. Louis, MO
Phone: (866) 649-4011
1311 Tower Grove Ave, St. Louis, MO
Phone: (866) 649-4011
Owner
St. Louis Board of Education
801 N. 11th Street, St. Louis, MO 63101
801 N. 11th Street, St. Louis, MO 63101
Billing
Attn: Advanced Elevator
PO Box 423, , MO 64601
PO Box 423, , MO 64601
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | conversion - reinspect | x | Phase 2 Firemans return call cancel does not operate. | 7/18/2018 | |
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | Machine room shall not be used to store non-elevator related materials. | 10/26/2020 | ||
A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | Emergency lighting is not operational. | 10/26/2020 | ||
A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1001.2(d)(12) | x | x | Car call cancel does not function on Phase 2 fire service. | 7/31/2019 |
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | The machine room shall not be used for the storage of non-elevator related items. | 10/26/2020 | ||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The elevator pit shall be kept clean and dry. | 10/26/2020 | ||
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | The machine room shall not be used for the storage of non-elevator related items. | 10/26/2020 | ||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | There were no keys on site to test fire service. Keys shall be kept on site and fire service shall be tested. | 10/20/2020 | |
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | Remove all non-elevator related items from the elevator machine room. | |||
A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | |||
A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | This elevator is equipped with an over speed valve and is due for a category 5 test. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | |||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO state operating certificate shall be displayed in the elevator machine room. | |||
A17.1-1996 : Elevators | 1.17 - Standby power operation | 1002.2g (Standby Power Operation) | x | Emergency battery lowering shall be operational. | 1/30/2023 | |
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit sump shall have a cover in place. | |||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current State Elevator Certificate. | |||
MO Minimum : Elevators | (A) - Hoistways | (A)9 | Unable to check in car stop switch upon Phase I recall,no key. |