Inspection
Inspection Details
Equipment ID
21271
21271
Inspection Date
2/9/2022
2/9/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Mark Brown
Mark Brown
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
18d7c112-f5a1-4ada-a90b-bcda6a988cd7
18d7c112-f5a1-4ada-a90b-bcda6a988cd7
Location
Michaels
1516 S Brentwood Blvd, Brentwood, MO
Phone: (314) 918-8189
1516 S Brentwood Blvd, Brentwood, MO
Phone: (314) 918-8189
Owner
Attn: MICHAEL'S c/o Pace Properties
Pace Properties- Brentwood
1401 S Brentwood Blvd, Brentwood, MO 63144
Phone: (469) 621-0908
Email: Shemika.Cole@vixxo.com
Pace Properties- Brentwood
1401 S Brentwood Blvd, Brentwood, MO 63144
Phone: (469) 621-0908
Email: Shemika.Cole@vixxo.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Replace broken combination teeth top and bottom | 2/9/2022 |
| conversion | conversion | conversion - reinspect | Yes | No | Demarcation lights out top and bottom | 2/9/2022 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current certificate. | 10/16/2025 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | 10/16/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5.2(i) Demarcation lighting | Yes | No | Repair top demarcation light | 10/8/2024 |
| Missouri Minimum : Escalators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Complete annual testing within 30 days, test brake torque | 10/8/2024 |
| A17.1-2016 : Elevators | 7.5 - Lighting | 6.1.7.1.1 | Yes | No | Top and bottom Demarcation lighting shall be wired to meet NFPA 70 | 8/7/2025 |
| A17.1-2016 : Elevators | 7.10 - Operating and safety devices | 6.1.6 | No | No | Repair upper and lower stop switch cover for proper operation. Alarm not sounding when lid is lifted | 10/16/2025 |
| A17.1-1996 : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | No | No | Post current State Elevator Certificate. | 10/16/2025 |
| Missouri Minimum : Escalators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Provide brake torque test, record results. | 10/16/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Indexing test failed, repair as needed. | 10/16/2025 |
| A17.1-1996 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 802.3e | Yes | No | Step indexing measurements were above allowable tolerances, need repaired. Re-inspection required |