Inspection
Inspection Details
Equipment ID
9592
9592
Inspection Date
2/18/2022
2/18/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas Sharp
Thomas Sharp
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
600
600
Slide
Governor Rope Pull
Door Closing Force
21
21
External ID
8df28d71-5220-4532-9fa8-ea96d2f9133d
8df28d71-5220-4532-9fa8-ea96d2f9133d
Location
Cambridge Senior Living Bldg
728 Biddle St, St. Louis, MO
Phone: (314) 436-9227
728 Biddle St, St. Louis, MO
Phone: (314) 436-9227
Owner
Attn: Cambridge Senior Living
Cambridge Senior Living
728 Biddle St, St. Louis, MO 63101
Phone: (314) 662-1830
Email: CambridgeSenior@mccormackbaron.com
Cambridge Senior Living
728 Biddle St, St. Louis, MO 63101
Phone: (314) 662-1830
Email: CambridgeSenior@mccormackbaron.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.27 - Crosshead data plate | 8.7.2.21 | No | No | Replace missing car data tag on crosshead. | 8/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - n/a | n/a | No | No | Clean oil and debris from pit. Reinspection required. | 8/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperable emergency phone. | 8/26/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean pit. | 2/12/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.9 Cleaning of Car Tops | No | No | Clean car top. | 2/12/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate. | 2/12/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to clean hydraulic fluid from pit. | 2/1/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 Gland Packings and Seals | No | No | Need to replace worn cylinder packing rings to reduce leakage | 6/24/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Tighten handrails inside the cab | 6/24/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to clean hydraulic fluid from elevator pit | 6/24/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to clean hydraulic fluid from elevator pit | 4/7/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 Gland Packings and Seals | No | No | Need to replace worn cylinder packing rings to reduce leakage | 4/7/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | OSV valve is due for full load test and tripping speed checked. Re-inspection required | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to clean hydraulic fluid from elevator pit | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 Gland Packings and Seals | No | No | Need to replace worn cylinder packing rings to reduce leakage |