Inspection
Inspection Details
Equipment ID
6773
6773
Inspection Date
2/8/2022
2/8/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Ross Colligan
Ross Colligan
Relief Valve Pressure
440
440
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
3cadc585-8dc6-41fe-b989-7a278ae45ddd
3cadc585-8dc6-41fe-b989-7a278ae45ddd
Location
Lindell Plaza Apts
4300 Lindell Blvd, St. Louis, MO
Phone: (314) 531-8642
4300 Lindell Blvd, St. Louis, MO
Phone: (314) 531-8642
Owner
Attn: Lindell Plaza Apts
Lindell Plaza Apts
4300 Lindell Blvd, St. Louis, MO 63108
Phone: (000) 000-0000
Email: spmrealtyllc@gmail.com
Lindell Plaza Apts
4300 Lindell Blvd, St. Louis, MO 63108
Phone: (000) 000-0000
Email: spmrealtyllc@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Need to test FEO Phase I | 5/3/2018 |
| conversion | conversion | n/a | No | No | Cab Ceiling lights shall be guarded. | 7/12/2021 |
| conversion | conversion | conversion - reinspect | Yes | No | Emergency light, bell and phone shall work. | 5/3/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Car recalls during phase 1 operation ; however, light creen not bypassed and cab fire service buzzer inoperative, repair | 7/25/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Guarded cab lighting | 7/25/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Replace ceiling tiles in car. | 7/12/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell inoperable and shall be repaired or replaced. | 3/19/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Repair or replace door open and close buttons inside he elevator. | 2/28/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Auxiliary lighting is inoperable and shall be repaired. | 2/27/2025 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7 | No | No | Auxiliary light is inoperable | 8/17/2026 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm inoperable. Re-inspection required | 8/17/2026 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7 | No | No | The cab ceiling is of the open egg-crate type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. It is missing a ceiling panel, ceiling needs to be repaired. | 8/17/2026 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7 | No | No | Car lighting (ceiling) if fluorescent bulbs and egg crate ceiling tile. Either guard bulbs or replace egg crate. Or upgrade to LED. | 8/18/2026 |