Inspection
Inspection Details
Equipment ID
7901
7901
Inspection Date
2/22/2022
2/22/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
Walter Tauchert
Walter Tauchert
Relief Valve Pressure
530
530
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
0f886ec4-34b1-4422-b715-4bf2731a4829
0f886ec4-34b1-4422-b715-4bf2731a4829
Location
Hampton Inn- St. Charles
3720 W CLAY ST, SAINT CHARLES, MO
Phone: (636) 947-6800
3720 W CLAY ST, SAINT CHARLES, MO
Phone: (636) 947-6800
Owner
Attn: 3720 W Clay Street LLC
3720 W Clay Street LLC
350 S Beverly Dr, Ste 300, Beverly Hills, CA 90212
Phone: (000) 000-0000
3720 W Clay Street LLC
350 S Beverly Dr, Ste 300, Beverly Hills, CA 90212
Phone: (000) 000-0000
Billing
Attn: Hampton Inn St Charles
Hampton Inn St Charles
3720 W Clay St, St. Charles, MO 63301
Phone: (636) 947-6800
Fax: (636) 947-0020
Email: stlst_hampton@hilton.com
Hampton Inn St Charles
3720 W Clay St, St. Charles, MO 63301
Phone: (636) 947-6800
Fax: (636) 947-0020
Email: stlst_hampton@hilton.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 2/27/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide a code compliant MCP including onsite documents. | 2/27/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 2/27/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 2/27/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | The car operating panel shall be marked with the identification number of the elevator - a minimum of 1/2 inches in heights and of contrasting color to its background. | 2/27/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Up-to-date wiring diagrams shall be provided and permanently kept in the machine room. The diagrams in the machine room are not correct for the controller and are illegible. | 2/27/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Currently an oil log, and in incorrect illegible copy of schematics are present. | 2/27/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Firefighters phase 2 "hold" function shall operate as required. | 2/27/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | When firefighters phase 2 is in effect with the doors in the normal open position and the in car key-switch in the off position, the car shall be captured and return to the designated floor. | 2/27/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 8/25/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 12/15/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Up-to-date wiring diagrams shall be provided and permanently kept in the machine room. Note: The diagrams in the machine room are not correct for the controller and are illegible. | 12/15/2025 |