Inspection
Inspection Details
Equipment ID
5846
5846
Inspection Date
8/24/2018
8/24/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Richard Dalman
Richard Dalman
Relief Valve Pressure
Slide
Governor Rope Pull
Na
Na
Door Closing Force
Na
Na
External ID
e1a78fd0-45eb-4581-8b07-8195cdf61e48
e1a78fd0-45eb-4581-8b07-8195cdf61e48
Location
Life Line Foods
2811 S 11TH STREET RD, SAINT JOSEPH, MO
2811 S 11TH STREET RD, SAINT JOSEPH, MO
Owner
Life Line Foods
2811 S 11TH STREET RD, SAINT JOSEPH, MO 64503-3461
2811 S 11TH STREET RD, SAINT JOSEPH, MO 64503-3461
Billing
Attn: Life Line Foods
2811 S 11TH STREET RD, SAINT JOSEPH, MO 64503-3461
2811 S 11TH STREET RD, SAINT JOSEPH, MO 64503-3461
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light does not illuminate. Repair pit lighting | 11/19/2018 | ||
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | Post fire service instructions inside and outside the elevator | 11/9/2018 | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Remove standing water on machine room floor. Condensation drain on machine room air conditioner is plugged | 10/1/2019 | ||
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.10.2.2.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Phone line monitoring verification does not function. | 7/2/2021 | |
| A17.1-2016 : Elevators | 2.14 - Code data plate | 8.7.1.8 | x | Post code data plate on controller listing code and edition in effect at time of alteration and requirements in section 8.7 that were applicable to the alteration. | 7/2/2021 | |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(d) | x | Post alteration acceptance metal tag with the applicable code requirements of section 8.10, date of test, name of person performing the test, inspector witnessing test, including inspectors ID number and certifying organization. | 7/2/2021 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.11 Runby (Re-Inspection) | x | Shorten hoist ropes for proper runby. Runby is less than 6 inches. | 7/2/2021 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | x | Install lockable pullbox cover over hoistway door unlocking device at landing 10 E | 7/2/2021 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.7.2 Periodic Test Record (Test Tags) | Provide and attach annual no load safety test tag. | 10/23/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.5 Code Data Plate | Provide code data plate reflecting the sections of 8.7 that were modernized or altered. | 10/23/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.7.2 Periodic Test Record (Test Tags) | Provide permanent metal test tag reflecting annual inspections in machine room. | 10/23/2023 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Remove trash, debris, and elevator components from pit. | 10/23/2023 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | Shorten main hoisting ropes, only 1" of CW runby in the pit. | 6/5/2023 | |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.4 | Provide clear access to pit access door, walk in pit application. | 10/23/2023 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | Provide lockable access point to access the top of the car from the top landing, pit access ok. | 10/23/2023 | ||
| A17.1-2016 : Elevators | 3.2 - Car top light and outlet | 2.14.7.1.4 | Replace car top light bulb, it did not turn on | 10/23/2023 | ||
| A17.1-2016 : Elevators | 3.9 - Floor and emergency identification numbering | 2.29.2 | The only rear opening hoistway door that is labeled on the hoistway side is floor 9, label all hoistway doors on the rear side | 10/23/2023 | ||
| A17.1-2016 : Elevators | 1.3 - Operating control devices | 2.26.1 | Rear door reset button on the car operating panel is missing and needs to be replaced (open hole in the car operating panel) | 10/23/2023 | ||
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone was not answered, emergency phone is to be answered 24/7 | 10/2/2023 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Rear door reset button on the car operating panel is missing and needs to be replaced | 10/30/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Front and rear Car gate astragals need to be replaced | 10/30/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | First floor hoistway door Astragal needs to be replace | 10/30/2024 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | 1st floor hoistway bottom door panel bent in, excessive gap between door and sill, straighten or replace door panel | 10/30/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Front side warning strobe is not working, repair strobe | 10/30/2024 | ||
| A17.1-2016 : Elevators | 2.6 - Ventilation | 2.7.9.2 | Repair the air conditioner in the machine room, need to keep the machine at the temperature and humidity rating required for the controller | |||
| A17.1-2016 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 2.15.2 | x | x | Replace worn out guide roller on the bottom of the car | |
| A17.1-2016 : Elevators | 4.2 - Hoistway doors | 2.11 | x | 1st floor hoistway bottom door panel bent in, excessive gap between door and sill, straighten or replace door panel | ||
| A17.1-2016 : Elevators | 4.1 - Car platform guard | 2.15.9 | Car platform guards are required to be 48 inches long when the car is equipped with unintended motion |