Inspection
Inspection Details
Equipment ID
18336
18336
Inspection Date
3/1/2022
3/1/2022
Inspection Type
Reinspection
Reinspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
Dustin Arnett
Dustin Arnett
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
09e6e643-c4b8-439d-912d-2be05bea2a3e
09e6e643-c4b8-439d-912d-2be05bea2a3e
Location
City Museum
701 N 15th St, St. Louis, MO
Phone: (314) 231-1009
701 N 15th St, St. Louis, MO
Phone: (314) 231-1009
Owner
Attn: AP
City Museum
701 N 15th St, Box #29, St. Louis, MO 63103
Phone: (000) 000-0000
Email: admin@citymuseum.org
City Museum
701 N 15th St, Box #29, St. Louis, MO 63103
Phone: (000) 000-0000
Email: admin@citymuseum.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | Replace the governor rope. | 2/26/2020 | |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | Each freight car enclosure shall have a "No Passengers" sign conspicuously posted. | 12/7/2020 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | The mainline disconnect duct shall have a cover installed. | 12/7/2020 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | Hoistway access means shall be provided at the top and bottom floor. | 12/7/2020 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The radiator in the machine room shall be properly fastened or removed. | 12/7/2020 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)5 | All hoistway doors shall have pull straps. | 12/7/2020 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | The car leveling device shall operate properly. | 9/28/2020 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | All the on site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 6/23/2022 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 6/23/2022 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)5 | Pull straps shall be installed on all hoistway doors. | 6/23/2022 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. | 6/23/2022 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)6 | Machines, motors, and disconnects shall be conspicuously marked. | 6/23/2022 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | The water on the machine room floor shall be removed, and the leak repaired. | 6/23/2022 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Access to the machine room shall be safe. The brickwork above the machine room door and on the stairway landing is falling down, and shall be repaired. | 6/23/2022 | ||
| MO Minimum : Elevators | (I) - Pits | (I)8 | The drain hole in the pit floor shall be covered flush with the floor. | 6/23/2022 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | The movement of the safety drum rope, starting from a fully retracted position, must not exceed 36". (It pulled out 60") | 3/1/2022 | |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)2 | Repair holes in car gate. Gates shall be constructed as to reject a ball two inches (2") in diameter. They shall withstand a force of two hundred fifty (250) pounds pressure applied in the center of the gate without breaking or forcing it out of its guides. | 12/8/2025 | ||
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)4 | top. The top may be solid or open-work construction and shall be of metal. The open work shall reject a ball two inches (2") in diameter. Car tops shall be constructed to sustain a load of two hun- dred (200) pounds applied at any point on the car top. The top shall not have hinged or folding panels other than the emergency exit cover. | 12/8/2025 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | Access means shall be provided at one (1) upper landing to permit access to the top of the car, and at the lowest landing if this landing is the normal point of access to the pit | 12/8/2025 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | Access means shall be provided at one (1) upper landing to permit access to the top of the car, and at the lowest landing if this landing is the normal point of access to the pit. | 12/8/2025 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Replace missing covers on exposed wiring on the car top and SOS switch. | 12/8/2025 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | The bolt holding the compensation chains is bent. The bolt needs to be straightened and possibly replaced | 12/8/2025 | ||
| MO Minimum : Elevators | (A) - Hoistways | (A)5 | Install pull straps on all hoistway doors and Gate | |||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Clean Pit |