Inspection
Inspection Details
Equipment ID
6772
6772
Inspection Date
3/19/2022
3/19/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
Kurt Warttig
Kurt Warttig
Relief Valve Pressure
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
n/a
n/a
External ID
4a4b4a8f-d60e-4ffd-a70a-0ca42fbb3ebd
4a4b4a8f-d60e-4ffd-a70a-0ca42fbb3ebd
Location
Ardagh
1500 Saint Gobain Dr, Pevely, MO
Phone: (636) 479-4421
1500 Saint Gobain Dr, Pevely, MO
Phone: (636) 479-4421
Owner
Attn: Cassidy Alonzo
Ardagh
1500 Ardagh Group Dr, Pevely, MO 63070
Phone: (636) 475-1144
Email: Cassidy.Alonzo@ardaghgroup.com
Ardagh
1500 Ardagh Group Dr, Pevely, MO 63070
Phone: (636) 475-1144
Email: Cassidy.Alonzo@ardaghgroup.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room door shall be self-closing. | 5/21/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Provide a current tested fire extinguisher in the elevator machine room. | 5/21/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Remove the extension cord from the machine room window. | 5/21/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Car top light shall work. | 5/21/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Clean the car top. | 5/21/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean. | 5/21/2020 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Provide working Phase 1 & Phase 2 fire service operation. | 8/23/2019 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Post Phase 1 fire service instructions near the fire service switch. | 8/23/2019 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Post Phase 2 fire service instructions near the fire service switch in the car. | 8/23/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room ceiling is leaking. The leak shall be repaired. | 5/21/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | The in car emergency telephone shall be operational. | 5/21/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | No | No | Telephone in car doesn't work. Phone line dead to elevator controller | 4/16/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean hoistway and pit. Excessive powder and debris | 4/16/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post Current Operating Certificate in Machine room | 11/17/2023 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Governor Rope showing rope rouge and diameter is below maximum allowable amount | 5/24/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell does not work when normal power is removed | 3/26/2025 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Phase 1 does not recall the elevator to the recall floor when the elevator is switched from Phase II to Phase I | 3/26/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.2 Replacement of Suspension Means (Re-Inspection) | Yes | No | Suspension ropes are showing rouge and the diameter has reduced beyond the maximum allowable amount. Replace suspension ropes. | 6/5/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The alarm ball does not work when normal power is removed | 6/5/2025 |