Inspection
Inspection Details
Equipment ID
13411
13411
Inspection Date
3/21/2022
3/21/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
300
300
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
5ff3dd08-d70f-47fa-84bf-2d73c5545a61
5ff3dd08-d70f-47fa-84bf-2d73c5545a61
Location
Holiday Inn-St. Louis Downtown
811 N 9th St, St. Louis, MO
Phone: (314) 421-4000
811 N 9th St, St. Louis, MO
Phone: (314) 421-4000
Owner
Attn: HMA Hotels
Holiday Inn-St.Louis Downtown Convention Center
811 N 9th St, St. Louis, MO 63101
Phone: (314) 421-4000
Fax: (314) 421-5974
Email: Rwhitnah@hmahotels.com
Holiday Inn-St.Louis Downtown Convention Center
811 N 9th St, St. Louis, MO 63101
Phone: (314) 421-4000
Fax: (314) 421-5974
Email: Rwhitnah@hmahotels.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Repair roof leak | 7/15/2019 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor | 7/15/2019 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pump drip pan | 7/15/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Replace jack packing | 7/15/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 7/15/2019 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Performed month fire service & test document on log in machine room | 4/27/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Remove Scavenger pump from pit | 4/27/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor | 4/27/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | 4/27/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Provide complete maintenance control program and include oil log | 4/27/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor | |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency communications in car not working | 3/13/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor. Reinspection required within 14 days/ Fire Hazard | |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine romm | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair phone in car. Reinspection within 14 days required |