Inspection
Inspection Details
Equipment ID
21191
21191
Inspection Date
4/12/2022
4/12/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Sam Cones
Sam Cones
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
18#
18#
External ID
f52bfc52-1673-4038-a258-2d218c0c956f
f52bfc52-1673-4038-a258-2d218c0c956f
Location
CMC-Assumption Hall
1900 Grand Ave, Carthage, MO
Phone: (000) 000-0000
1900 Grand Ave, Carthage, MO
Phone: (000) 000-0000
Owner
Attn: Congregation of the Mother of Coredemptrix
Congregation of the Mother of Coredemptrix
1900 Grand Ave, Carthage, MO 64836
Phone: (417) 358-7787
Email: quanlycmc@gmail.com
Congregation of the Mother of Coredemptrix
1900 Grand Ave, Carthage, MO 64836
Phone: (417) 358-7787
Email: quanlycmc@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | pit needs to be dry and clean--check sump pump | 6/3/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | No | No | fire extinguisher hasn't been checked since 2014 | 6/3/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | needs current certificate posted in machine room | 7/30/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | telephone will not call out | 7/31/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State operating certificate in machine room | 7/30/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired) | 9/1/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location, Rings but no answer (REINSPECTION REQUIRED) | 4/12/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | Car Door restrictor shall work. (REINSPECTION REQUIRED) | 4/12/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | H(2) / 101.3d(1)(b) Machine room door shall be self-closing and self-locking | 9/1/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | H(2) / 101.3d(1)(b) Machine room door shall be self-closing and self-locking 2021&2022 violation | 9/1/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location, Rings but no answer (REINSPECTION REQUIRED) | 4/12/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | Car Door restrictor shall work. (REINSPECTION REQUIRED) | 4/12/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Provide operational telephone in elevator cab | 5/1/2023 |