Inspection
Inspection Details
Equipment ID
218
218
Inspection Date
3/31/2022
3/31/2022
Inspection Type
Reinspection
Reinspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Benjamin Kurzava
Benjamin Kurzava
Relief Valve Pressure
Slide
7"
7"
Governor Rope Pull
100/430
100/430
Door Closing Force
18/22
18/22
External ID
dd337543-88c0-4286-91e0-1a4c6a0d59af
dd337543-88c0-4286-91e0-1a4c6a0d59af
Location
Heritage Towers
515 W MOUNT VERNON ST, SPRINGFIELD, MO
Phone: (417) 207-4888
515 W MOUNT VERNON ST, SPRINGFIELD, MO
Phone: (417) 207-4888
Owner
Attn: Chuck Hicks
Springfield Housing Authority
421 W Madison St, Springfield, MO 65806
Phone: (417) 207-4888
Email: Chicks@hasproperties.org
Springfield Housing Authority
421 W Madison St, Springfield, MO 65806
Phone: (417) 207-4888
Email: Chicks@hasproperties.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 2.17 machine noisey--determine cause & repair or replace parts | 1/30/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.18 - Traction drive machines | 8.11.2.1.2(p) | Yes | No | 1/5/21: Machine very noisy. Determine cause and repair/replace needed parts. REINSPECTION REQUIRED | 8/11/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.18 - Traction drive machines | 8.11.2.1.2(p) | Yes | No | Machine very noisy. Determine cause and repair/replace needed parts. REINSPECTION REQUIRED | 8/11/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | VIO1. B(11)/1.6.1/ : 2-way communication device shall work and give proper location (REINSPECTION 14days to REDTAG | 3/31/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | VIO3. G(1)1.18.1/8.6.4.13.1(l): Car Door restrictor shall work. (Front) | 3/31/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | VIO4. G(1) Car-top light not working, clean cartop,clean pit | 5/3/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | VIO5. I(5). : Pit Ladder shall be installed , accessible from each Pit access opening for each elevator. (#217 has a ladder but not accessible from #218 pit) | 5/3/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | VIO6. G(1). Replace non-functional lamp in Emergency Light fixture (1 of 2 lamps not working) | 3/31/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | VIO2. TESTING INCOMPLETE. Fire Service and Door# be tested to complete. F.S. Keys needed | 3/31/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean pit | 5/3/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | VIO1. B(11)/1.6.1/ : 2-way communication device shall work and give proper location (REINSPECTION 14days to REDTAG | 3/31/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | VIO3. G(1)1.18.1/8.6.4.13.1(l): Car Door restrictor shall work. (Front) | 3/31/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | VIO2. TESTING INCOMPLETE. Fire Service and Door# be tested to complete. F.S. Keys needed | 3/31/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | Provide pit ladder #217 has one but not accessible from #218 | 6/26/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Provide MCP in machine room | 5/3/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Car hoist ropes undersized, replace per code | 8/5/2024 |