Inspection
Inspection Details
Equipment ID
15134
15134
Inspection Date
4/4/2022
4/4/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
James Dalton
James Dalton
Relief Valve Pressure
Slide
N/a
N/a
Governor Rope Pull
N/a
N/a
Door Closing Force
12
12
External ID
6ca715df-c72f-4281-990c-0ba7d8b071b5
6ca715df-c72f-4281-990c-0ba7d8b071b5
Location
Roosevelt Town Apts
711 N Euclid Ave, St. Louis, MO
Phone: (314) 361-7330
711 N Euclid Ave, St. Louis, MO
Phone: (314) 361-7330
Owner
Attn: NCR
NCR
2335 N Bank Dr, Columbus, OH 43220
Phone: (000) 000-0000
NCR
2335 N Bank Dr, Columbus, OH 43220
Phone: (000) 000-0000
Billing
Attn: Roosevelt Towne Apts
Roosevelt Towne Apts
711 N Euclid Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Email: 0852@nationalchurchresidences.org
Roosevelt Towne Apts
711 N Euclid Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Email: 0852@nationalchurchresidences.org
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Door restrictor is inoperable. When a car is outside the unlocking zone, the car doors shall be so arranged that when in the closed position they shall be restricted from opening | 1/5/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Bulbs and tubes shall be guarded to prevent breakage | 8/16/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Provide Phase II Fire Service Instructions on Car Operating Panel | 8/16/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Phone in car fails to establish two-way communication | 1/5/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Seal penetrations in hoistway from basement demolition. Hoistways containing passenger elevators shall be fully enclosed and the enclosure shall be of solid construction to its full height | 8/16/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Hole in pit must be fully enclosed | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit shall be kept clean & dry | |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | Pit ladder must be fixed or replaced | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. Re-inspection required | 7/1/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)1 | No | No | Replace missing car hand rail. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Clean car top. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Clean down hoistway. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Clean the pit. | |
| MO Minimum : Elevators | (I) - Pits | (I)4 | No | No | Pit ladder is UNSAFE. Repair or replace. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Provide existing phone to work properly. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | Hoistway door, 7th floor, bottom door guide missing screw dragging sill. Repair as needed. | |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Hoistway walls damaged (water) drywall missing. Replace. | |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Car emergency light, only one bulb working-two required. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Provide machine room door to be self closing and self locking. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Provide car speed adjusted to contract speed. Currently running 165-170 rpm. | |
| A17.1-1996 : Elevators | 5.4 - Normal terminal stopping devices | 1002.2e | Yes | No | While on car top inspection, car ran past directional and onto final. Adjust as needed. |