Inspection
Inspection Details
Equipment ID
18258
18258
Inspection Date
8/25/2017
8/25/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Relief Valve Pressure
580
580
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
30
30
External ID
18258
18258
Location
Metro Link-Skinker
260 N Skinker, St. Louis, MO
Phone: (314) 289-6870
260 N Skinker, St. Louis, MO
Phone: (314) 289-6870
Owner
Metro Link
707 N First St, St. Louis, MO 63102
707 N First St, St. Louis, MO 63102
Billing
Attn: Metro/STL
707 N 1st St, , MO 63102
707 N 1st St, , MO 63102
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone not working. | 4/8/2019 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Emergency light not working. | 3/10/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm bell not working. | 8/6/2020 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display updated certificate in machine room. | 3/10/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Need maintenance control plan on site posted on controller | 12/7/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 12/7/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light in car not working | 7/12/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Owner is responsible for monthly fire service testing to be logged on the fire service log and placed on the controller in machine room | 12/7/2021 |
| A17.1-1996 : Elevators | 1.14 - Ventilation | 204.2c | Yes | No | Elevator cab ventilation fan does not work on auxiliary power, needs repaired. Re-inspection required | 10/26/2023 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1002.2g (Standby Power Operation) | Yes | No | Elevator cab ventilation still does not work on auxiliary power. Re-inspection required | 7/23/2024 |
| A17.1-1996 : Elevators | 1.14 - Ventilation | 204.2c | Yes | No | Elevator cab ventilation fan does not work on auxiliary power (battery backup), needs repaired. Re-inspection required | 10/10/2024 |
| A17.1-1996 : Elevators | 1.14 - Ventilation | 204.2c | Yes | No | Elevator cab ventilation fan does not work on auxiliary power (battery backup) Repair fan. Re-inspection required | 11/4/2025 |