Inspection
Inspection Details
Equipment ID
3786
3786
Inspection Date
4/29/2022
4/29/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Shaun Deckard
Shaun Deckard
Relief Valve Pressure
430
430
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
c83cac51-c1a2-4b8e-8733-e2b0edd141d5
c83cac51-c1a2-4b8e-8733-e2b0edd141d5
Location
Hope Spring
3901 E 32nd St, Joplin, MO
Phone: (417) 621-6341
Email: DAPerry2@FreemanHealth.com
3901 E 32nd St, Joplin, MO
Phone: (417) 621-6341
Email: DAPerry2@FreemanHealth.com
Owner
Ozark Center- Joplin
3901 E 32ND ST, JOPLIN, MO 64804-3312
3901 E 32ND ST, JOPLIN, MO 64804-3312
Billing
Attn: Ozark Center- Joplin
PO BOX 2526, JOPLIN, MO 64803-2526
PO BOX 2526, JOPLIN, MO 64803-2526
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | pit needs to be dry and clean | 3/13/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | 1.06 gtelephone does not work | 2/25/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Telephone has no dial tone | 5/29/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light does not work | 5/29/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) . | 4/8/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | Battery Lowering shall work. Repair. REINSPECTION REQUIRED =/> 5/30/22 | 2/10/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | Pit shall be kept dry. Standing Water on pit equipment. Clean pit and pit steel for reinspection of C-channels and pipe stands for possible replacement. REINSPECTION REQUIRED =/> 5/30/22 | 2/10/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | Top emergency exit shall be secured properly. | 4/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | jack drain tubes shall be routed to a measurable container in the pit. Currently routed straight to tank. | 4/8/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Must post current Stat operating Cert. 5.100(2) | 4/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Must Make Emergency Phone operable. Reinspection required in 14 days | 3/25/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Pit equipment must be cleaned to remove rust and re-painted. 8.6.4.7 | 4/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Must provide means to collect and Monitor jack packing gland oil usage. 8.6.5.5.2 | 4/8/2025 |