Inspection
Inspection Details
Equipment ID
11199
11199
Inspection Date
4/20/2022
4/20/2022
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Sean Carmody
Sean Carmody
Mechanic Name
Jeffrey Miller
Jeffrey Miller
Relief Valve Pressure
460
460
Slide
Governor Rope Pull
Door Closing Force
22
22
External ID
118867b6-bd4f-4930-a0af-b98b0c3bdc7b
118867b6-bd4f-4930-a0af-b98b0c3bdc7b
Location
Schicker Automotive
3300 S KINGSHIGHWAY BLVD, SAINT LOUIS, MO
Phone: (314) 450-7154
3300 S KINGSHIGHWAY BLVD, SAINT LOUIS, MO
Phone: (314) 450-7154
Owner
Attn: Schicker Automotive
Schicker Automotive
3300 S KINGSHIGHWAY BLVD, SAINT LOUIS, MO 63139
Phone: (314) 664-4100
Email: terry@schickerautomotive.com
Schicker Automotive
3300 S KINGSHIGHWAY BLVD, SAINT LOUIS, MO 63139
Phone: (314) 664-4100
Email: terry@schickerautomotive.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Pit light shall work. | 6/22/2018 |
| conversion | conversion | n/a | No | No | Machine room shall not be used for storage of non-elevator related materials. | 6/22/2018 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | 4/12/2023 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 4/12/2023 |
| A17.1-1996 : Elevators | 2.14 - Code data plate | 1200.6 | No | No | The code data plate required by A17.1 2016, section 8.9, shall be provided in plain view, securely attached to each main line disconnect or controller. | 4/12/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Up to date operating certificate is required in the machine room. | 4/12/2023 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 4/7/2023 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | No | No | Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag. | 4/12/2024 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | No | No | MCP Fire service testing must be properly documented monthly on log sheet. | 4/12/2024 |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2b (Clean Machine Room) | No | No | Non-elevator related items shall not be stored in machine room (shredder, paperwork, sorter). | 4/12/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Jack drain tube to be routed to a measurable container in pit, currently 1 jack drains straight to tank. | 4/12/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Car-top stop switch box missing knock-out hole cover, exposed electrical wires. | 4/12/2024 |