Inspection
Inspection Details
Equipment ID
20371
20371
Inspection Date
8/30/2018
8/30/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Bobby Joe Mehrens
Bobby Joe Mehrens
Relief Valve Pressure
550
550
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
801099e9-f28e-4f97-bdd9-bc9c66e5e42a
801099e9-f28e-4f97-bdd9-bc9c66e5e42a
Location
Boehringer Ingelheim Vetmedica Inc
2621 N BELT HWY, SAINT JOSEPH, MO
2621 N BELT HWY, SAINT JOSEPH, MO
Owner
Boehringer Ingelheim Vetmedica Inc
2621 N BELT HWY, SAINT JOSEPH, MO 64506-2002
2621 N BELT HWY, SAINT JOSEPH, MO 64506-2002
Billing
Attn: Boehringer Ingelheim Vetmedica Inc
2621 N BELT HWY BLDG F, SAINT JOSEPH, MO 64506-2002
2621 N BELT HWY BLDG F, SAINT JOSEPH, MO 64506-2002
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Plunger packing leaks excessively. Replace plunger seal. | 8/5/2019 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | post emergency evacuation of passengers form inside machine room | 3/15/2021 |
| A17.1-2016 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Room and Machinery Space | No | No | remove rags from machine room floor. | 3/15/2021 |
| A17.1-2016 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 | No | No | need to empty overflowing pit can. | 3/15/2021 |
| A17.1-2016 : Elevators | 2.33 - Tanks | 8.6.5.7 | No | No | monitor use of hydraulic oil with written log in machine room. | 3/15/2021 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | remove oil and oil soaked absorbent pads from pit. | 3/15/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.8 Switch Keys (Re-Inspection) | Yes | No | provide firefighter key in machine room or on site . | 4/12/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | Emergency light does not illuminate | 7/7/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | Emergency light does not illuminate | 1/13/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | No maintenance control plan on site | 3/21/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(a)(1) | No | No | No maintenance records on site | 3/21/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current state operating certificate not displayed in machine room | 3/21/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.9 - Floor and emergency identification numbering | 2.29.2 | No | No | HOISTWAYS SHALL HAVE FLOOR NUMBERS, NOT LESS THAN 4'' IN HEIGHT, ON THE HOISTWAY SIDE OF THE ENCLOSURE OR HOISTWAY DOORS |