Inspection
Inspection Details
Equipment ID
14766
14766
Inspection Date
5/3/2022
5/3/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
Mark Woronowicz
Mark Woronowicz
Relief Valve Pressure
410
410
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
700a5f96-d432-4c90-9ba7-8d89e964a031
700a5f96-d432-4c90-9ba7-8d89e964a031
Location
Oxford Hill Condominiums
10374 Chimney Rock Dr, St. Louis, MO
Phone: (314) 993-2227
10374 Chimney Rock Dr, St. Louis, MO
Phone: (314) 993-2227
Owner
Attn: 10358 Chimney Rock Dr
10358 Chimney Rock Dr
10358 Chimney Rock Dr, St. Louis, MO 63132
Phone: (000) 000-0000
10358 Chimney Rock Dr
10358 Chimney Rock Dr, St. Louis, MO 63132
Phone: (000) 000-0000
Billing
Attn: Nicole McGraw
Manor Condominiums at Oxford Hill c/o Sentry Management Inc
9666 Olive Blvd, Ste 116, St. Louis, MO 63132
Phone: (314) 994-7440 Ext: 57518
Email: nmcgraw@sentrymgt.com
Manor Condominiums at Oxford Hill c/o Sentry Management Inc
9666 Olive Blvd, Ste 116, St. Louis, MO 63132
Phone: (314) 994-7440 Ext: 57518
Email: nmcgraw@sentrymgt.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Hoistway doors shall have fire stops | 10/8/2019 |
| conversion | conversion | n/a | No | No | Car door force shall be less than 30 | 10/8/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current Operating Certificate in Machine Room | 8/1/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.4 Plunger Gripper Testing | No | No | Plunger Gripper due to be tested with rated load recurring every 5 years. | 8/1/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.5 - Normal terminal stopping device | 8.11.2.1.3(g) | Yes | No | Car shall have functioning Normal Terminal Limits actuating before Final Terminal Limit. | 6/28/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.1 Making Safety Devices Inoperative or Ineffective (Re-Inspection) | No | No | Relocate Plunger Gripper encoder so that it is not struck by the car during the stop ring pressure test | 8/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.1 Making Safety Devices Inoperative or Ineffective (Re-Inspection) | No | No | Final limit Cam strikes overhead during stop ring pressure test | 8/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone fails to establish two-way communication. | 5/8/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone fails to establish two-way communication. | 5/15/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher i nthe machine room is due to be serviced or replaced | 6/10/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room doors shall be self closing | 6/10/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher in the machine room is due to be serviced or replaced | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room doors shall be self closing |