Inspection
Inspection Details
Equipment ID
8270
8270
Inspection Date
5/5/2022
5/5/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
22
22
External ID
28489c1d-01b1-456f-85d2-b9648d49a349
28489c1d-01b1-456f-85d2-b9648d49a349
Location
Washington Apartments
600 N Kingshighway Blvd, St. Louis, MO
Phone: (314) 335-2766
600 N Kingshighway Blvd, St. Louis, MO
Phone: (314) 335-2766
Owner
Attn: Washington Apartments
Washington Apartments
600 N KINGSHIGHWAY BLVD, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
Email: Tammie.Townsend@McCormackBaron.com
Washington Apartments
600 N KINGSHIGHWAY BLVD, SAINT LOUIS, MO 63108
Phone: (000) 000-0000
Email: Tammie.Townsend@McCormackBaron.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | Yes | No | The car door restrictor device shall be repaired so that it will properly catch and restrict opening of the car doors to maximum of 4 inches when the car is away from the landing zone. | 9/10/2019 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | Clean water and debris from elevator pit. | 6/5/2020 |
| A17.1-1996 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 1001.2(e)(2) | Yes | No | Shorten hoist cables for proper runby clearance. | 8/19/2020 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Lost phone signal. Repair | 4/30/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Re-inspection required | 11/30/2023 |
| A17.1-1996 : Elevators | 2.3 - Lighting and receptacles | 101.5a Lighting | No | No | Repair all lighting in machine room to provide proper illumination. | 10/31/2025 |
| A17.1-2016 : Elevators | 1.1 - Door Reopening Device | 8.6.4.13.1(c) | Yes | No | Replace car door reopening device. Re-inspection required | 11/30/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned | 10/31/2025 |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3a | No | No | Safe access to machine room shall be provided, repair lighting in stairway to roof. | 10/31/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace bad door hanger roller on 3rd floor. | 10/31/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Need to clean car top | 10/31/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)2 | No | No | Pit channels, buffer supports, guide raills are rusted. Remove rust and apply inhibitor to prevent further damage or replace affected equipment. | 10/31/2025 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Elevator did not respond to Fire Fighter's Phase I recall keyswitch in lobby. Red-tagged, Re-inspection reqired | 11/30/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Re-inspection required | 1/29/2024 |
| A17.1-1996 : Elevators | 2.3 - Lighting and receptacles | 101.5a Lighting | No | No | Repair all lighting in machine room to provide proper illumination. | 10/31/2025 |
| A17.1-2016 : Elevators | 1.1 - Door Reopening Device | 8.6.4.13.1(c) | Yes | No | Replace car door reopening device. Re-inspection required | 1/29/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned. | 10/31/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace bad door hanger roller on 3rd floor. | 10/31/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Need to clean car top. | 10/31/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)2 | No | No | Pit channels, buffer supports, guide raills are rusted. Remove rust and apply inhibitor to prevent further damage or replace affected equipment. | |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Elevator did not respond to Fire Fighter's Phase I recall keyswitch in lobby.Elevator is not able to operate on normal operation due to the door reopening device not being operational. Red-tag shall remain on elevator. Re-inspection and repair required. | 1/29/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Re-inspection required | 6/7/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Repair all lighting in machine room to provide proper illumination | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Need to replace bad door hanger roller on 3rd floor | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Need to clean car top | |
| MO Minimum : Elevators | (I) - Pits | (I)2 | No | No | Pit channels, buffer supports, guide rails are rusted. Need to remove rust and apply inhibitor to prevent further damage or replace affected equipment. | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperative emergency phone |