Inspection
Inspection Details
Equipment ID
18088
18088
Inspection Date
5/11/2022
5/11/2022
Inspection Type
Reinspection
Reinspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
Relief Valve Pressure
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
n/a
n/a
External ID
c2fb289e-448a-4107-85f5-a6ad878419d3
c2fb289e-448a-4107-85f5-a6ad878419d3
Location
Fashion Square Lofts
1307 Washington Ave, St. Louis, MO
Phone: (314) 621-6262
1307 Washington Ave, St. Louis, MO
Phone: (314) 621-6262
Owner
Attn: Fashion Square Lofts
Fashion Square Lofts LLC
4439 OLD ALTON RD, GRANITE CITY, IL 62040
Phone: (314) 621-9292
Fashion Square Lofts LLC
4439 OLD ALTON RD, GRANITE CITY, IL 62040
Phone: (314) 621-9292
Billing
Attn: Fashion Square Lofts
Fashion Square Lofts LLC
1307 WASHINGTON AVE, SAINT LOUIS, MO 63103
Phone: (314) 621-9292
Email: matt@mbdstl.com
Fashion Square Lofts LLC
1307 WASHINGTON AVE, SAINT LOUIS, MO 63103
Phone: (314) 621-9292
Email: matt@mbdstl.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | All the on site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 1/12/2026 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/12/2026 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | An ABC type fire extinguisher with a current test tag shall be mounted convenient to the machine room door. | 1/12/2026 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit light shall be operational. | 1/12/2026 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | The in car emergency lighting shall be operational. | 2/28/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 2/28/2022 |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 1001.2(c)(18) | No | No | The load weigher control system in the overhead shall have the cover installed. | 1/12/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | The car gate switch shall be adjusted to open (and stop the driving machine) when the gate exceeds 2" from the fully closed position. | 2/28/2022 |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) | No | No | The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. | 1/12/2026 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Red Tag) | Yes | Yes | In car emergency phone, alarm bell, and emergency light are inoperable | 3/8/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm Bell and Emergency Light do not work when on backup power | 5/11/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Alarm bell does not work on normal or backup power | 3/28/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency Alarm bell does not work on normal or backup power | 2/27/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Alarm bell does not work on normal or backup power | 7/8/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | Pit sump holes, with or without pumps, and well holes that are accessible, shall be covered flush with the pit floor. The covering shall consist of a noncombustible material. | 1/12/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Alarm bell does not work on normal or backup power | 9/15/2025 |