Inspection
Inspection Details
Equipment ID
11798
11798
Inspection Date
4/26/2022
4/26/2022
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
Jeffrey Miller
Jeffrey Miller
Relief Valve Pressure
530
530
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
b1f49873-801a-433b-bc6f-0b91501569bc
b1f49873-801a-433b-bc6f-0b91501569bc
Location
Fellowship of Wildwood
17770 Mueller Rd, Wildwood, MO
Phone: (636) 230-8900
17770 Mueller Rd, Wildwood, MO
Phone: (636) 230-8900
Owner
Attn: Fellowship of Wildwood
Fellowship of Wildwood
17770 MUELLER RD, WILDWOOD, MO 63038
Phone: (636) 324-7175
Email: alissa@fellowshipofwildwood.org
Fellowship of Wildwood
17770 MUELLER RD, WILDWOOD, MO 63038
Phone: (636) 324-7175
Email: alissa@fellowshipofwildwood.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone not working, maybe no phone line | 6/4/2020 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 3/8/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/8/2023 |
| A17.1-1996 : Elevators | 2.14 - Code data plate | 1200.6 | No | No | The code data plate required by A17.1 2016, Section 8.9, shall be provided in plain view, securely attached to each main line disconnect or controller. | 3/8/2023 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1001.2(a)(17) | Yes | No | The emergency lowering device (ERU) shall be operational. | 3/7/2022 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | 3/8/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 5/17/2022 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | There is oil in the pit. Clean the pit and correct source of oil leak. | 5/30/2024 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | Yes | No | Car door does not automatically close when fire operation is turned off. | 5/30/2024 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Oil shall not be allowed to accumulate on pit floor. Oil on the pit floor shall be removed. | 4/24/2025 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | No | No | Fire service testing shall be documented monthly. | 5/21/2025 |
| A17.1-1996 : Elevators | 1.7 - Car door or gate | 204.4 | Yes | No | Door restrictor shall work. |