Inspection
Inspection Details
Equipment ID
2142
2142
Inspection Date
5/12/2022
5/12/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Mitchell McNeely
Mitchell McNeely
Mechanic Name
Brenton Lane
Brenton Lane
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
0cc9a981-2333-415a-9eaf-32ba5007f948
0cc9a981-2333-415a-9eaf-32ba5007f948
Location
St. Raymond's Apartments
1015 Park Ave, St. Louis, MO
Phone: (314) 241-7838
1015 Park Ave, St. Louis, MO
Phone: (314) 241-7838
Owner
Attn: St. Raymonds Apts Assocs, LP c/o Sansone Group
St. Raymonds Apts Assocs, LP c/o Sansone Group
120 S CENTRAL AVE STE 500, SAINT LOUIS, MO 63105
Phone: (314) 336-3368
Email: kdurrwachter@sansonegroup.com
St. Raymonds Apts Assocs, LP c/o Sansone Group
120 S CENTRAL AVE STE 500, SAINT LOUIS, MO 63105
Phone: (314) 336-3368
Email: kdurrwachter@sansonegroup.com
Billing
Attn: St. Raymonds Apts
St. Raymonds Apts
1015 Park Ave, SAINT LOUIS, MO 63104
Phone: (314) 336-3368
Email: nhammett@sansonegroup.com
St. Raymonds Apts
1015 Park Ave, SAINT LOUIS, MO 63104
Phone: (314) 336-3368
Email: nhammett@sansonegroup.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperative emergency phone. | 6/24/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/8/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room shall not be used to store non-elevator related equipment. | 7/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall work. | 9/26/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 7/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | In car stop switch shall be conspicuously and permanently marked "STOP" and shall indicate the stop and run positions; Faded and Unreadable. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Telephone Door Handle is missing. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | COP shall have car number displayed(multiple units onsite) | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room lighting needs to be repaired, 1 or more bulbs not working. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | MACHINE ROOM - Phone box obstructs the fully opening of the card rack. Relocation phone box. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | MACHINE ROOM - Outlet is overloaded. 3 separate heating systems plugged into 1 outlet, Phone system plugged into other outlet. No available outlets for tools. Heating systems shall be permanently/properly wired . | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | MACHINE ROOM - Phone box is wired to an extension cord that runs across the controller to an adapter installed in the machine room light fixture (Non-compliant). Remove extension cord and properly power phone box. |