Inspection
Inspection Details
Equipment ID
9741
9741
Inspection Date
5/9/2022
5/9/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Ledden
Michael Ledden
Mechanic Name
Dustin Arnett
Dustin Arnett
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
f8604da0-7edb-42a2-9450-84c5b4137fc7
f8604da0-7edb-42a2-9450-84c5b4137fc7
Location
5616 Pershing Bldg
5616 Pershing Ave, St. Louis, MO
Phone: (314) 367-5650
5616 Pershing Ave, St. Louis, MO
Phone: (314) 367-5650
Owner
Attn: Mark
Hamilton Horton 1999 Apts Co LLC
PO Box 410029, St. Louis, MO 63141
Phone: (314) 367-5650
Email: mark.jaffe@mjaffegroup.com
Hamilton Horton 1999 Apts Co LLC
PO Box 410029, St. Louis, MO 63141
Phone: (314) 367-5650
Email: mark.jaffe@mjaffegroup.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | A fire extinguisher is required in the elevator machine room. | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display the current state operating certificate in the machine room. | |||
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | A17.1 - 8.11.2.1.3(t) - The distance from the face of the hoistway doors to the edge of the hoistway landing sills shall not be more than 5". | |||
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)4 | The car top shall be metal and shall sustain a load of 200 lbs. applied to any point on the car top. The car top shall be securely fastened and an emergency escape hatch provided. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | The car top lighting shall be relocated to allow for proper clearance. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be obtained and displayed in the elevator machine room. | |||
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | A "No Passengers" sign shall be posted in the elevator cab. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | The machine room lighting shall be not less than 10 foot-candles at floor level. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | There is no fire extinguisher in the machine room. An ABC type fire extinguisher with a current test tag shall be provided in the machine room. | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 5/9/2024 | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Machine room light shall be at least 10 fc and be guarded. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | A "No Passengers" sign shall be posted in the elevator cab. This is a multi-year violation. Failure to correct the violation may result in unit being red tagged until completed. | |||
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)4 | The cartop shall be metal and shall sustain a load of 200 lbs applied to any point on the car top. The car top shall be securely fastened and an emergency escape hatch provided. This is a multi-year violation. Failure to correct the violation may result in unit being red tagged until completed. | |||
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | x | The distance from the face of the hoistway doors to the edge of the hoistway landing sills shall not be more than 5". | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Machine room light shall be at least 10 fc and be guarded. This is a multi-year violation. Failure to correct the violation may result in unit being red tagged until completed. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The machine room door shall be self-closing and self-locking and shall be operable from the interior space without the use of a key. This is a multi-year violation. Failure to correct the violation may result in unit being red tagged until completed. |