Inspection
Inspection Details
Equipment ID
13872
13872
Inspection Date
8/14/2018
8/14/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Herbert Neulist
Herbert Neulist
Mechanic Name
Brian Thieme
Brian Thieme
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
090fbf08-e15f-4a58-bb06-d70b6849df60
090fbf08-e15f-4a58-bb06-d70b6849df60
Location
Hollywood Casino St. Louis
777 CASINO CENTER DR, MARYLAND HEIGHTS, MO
777 CASINO CENTER DR, MARYLAND HEIGHTS, MO
Owner
Hollywood Casino St. Louis
777 CASINO DR, MARYLAND HEIGHTS, MO 63043
777 CASINO DR, MARYLAND HEIGHTS, MO 63043
Billing
Attn: Hollywood Casino St. Louis
777 CASINO CENTER DR, MARYLAND HEIGHTS, MO 63043-4821
777 CASINO CENTER DR, MARYLAND HEIGHTS, MO 63043-4821
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Demarcation lights top and bottom are out. Recommend truss and pit clean down. | 8/31/2022 |
| conversion | conversion | n/a | No | No | Demarcation lights top and bottom are out. Recommend truss and pit clean down. | 8/31/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(H) | No | No | All demarcation lights shall work. | 8/31/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(K) | No | No | Replace left handrail. | 8/31/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(D) | No | No | Repair bad step chains. | 8/31/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(D) | No | No | Broken weld on step track. | 8/31/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(A) | No | Yes | Failed brake test. Red tagged out of service until repaired and reinspected. | 8/28/2020 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(E) | No | No | Bad comb impact switch. | 8/31/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | Replace left handrail. | 8/31/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | Right handrail is cracked. Replace handrail | 8/31/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(E) | Yes | No | Replace broken comb plate at top landing. Re-inspection required | 11/7/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | Left handrail has cracks, needs to be replaced | 12/1/2024 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.6 Steps | Yes | No | Need to replace broken step demarcation strip. Re-inspection required | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Test is incomplete, need to perform test to check tripping pressure of upper and lower comb plate impact devices & perform step indexing test. Re-inspection required |