Inspection
Inspection Details
Equipment ID
14768
14768
Inspection Date
6/2/2022
6/2/2022
Inspection Type
Other Inspection
Other Inspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
Kurt Warttig
Kurt Warttig
Relief Valve Pressure
n/a
n/a
Slide
Governor Rope Pull
Door Closing Force
External ID
45bad371-5780-420a-9db6-146a43757586
45bad371-5780-420a-9db6-146a43757586
Location
10358 Chimney Rock Dr
10358 Chimney Rock Dr, St. Louis, MO
Phone: (314) 799-1506
10358 Chimney Rock Dr, St. Louis, MO
Phone: (314) 799-1506
Owner
Attn: 10358 Chimney Rock Dr
10358 Chimney Rock Dr
10358 Chimney Rock Dr, St. Louis, MO 63132
Phone: (000) 000-0000
10358 Chimney Rock Dr
10358 Chimney Rock Dr, St. Louis, MO 63132
Phone: (000) 000-0000
Billing
Attn: Nicole McGraw
Manor Condominiums at Oxford Hill c/o Sentry Management Inc
9666 Olive Blvd, Ste 116, St. Louis, MO 63132
Phone: (314) 994-7440 Ext: 57518
Email: nmcgraw@sentrymgt.com
Manor Condominiums at Oxford Hill c/o Sentry Management Inc
9666 Olive Blvd, Ste 116, St. Louis, MO 63132
Phone: (314) 994-7440 Ext: 57518
Email: nmcgraw@sentrymgt.com
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Machine room light shall be guarded | |||
conversion | conversion | n/a | No current state operation certificate in elevator machine room. | |||
conversion | conversion | n/a | Car door closing force in excess of 30lbs | |||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)12 (Door open zones) | car door restrictor does not work. | 10/17/2019 | ||
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | test phase 1 and 2 fire service. | 10/17/2019 | |
MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)6 | x | x | test life jacket type safety with full load. reinspection required. not a red tag. | 10/17/2019 |
MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Repair machine room lighting. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Secure gutter under piping in machine room (head clearance issue). | |||
MO Minimum : Elevators | (A) - Hoistways | (A)16 | Large electric junction box in hoistway is missing its cover. Reinstall. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | x | Large head for floor leveling was torn off during stop ring test. No part of the car shall strike the overhead. | 12/3/2019 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Test elevator cab phone. | 12/3/2019 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Relocate car top selector tape bracket. Selector hits bracket when doing stop ring pressure test. | |||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current operating certificate in machine room | 8/1/2022 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. (Oil and rags in Pit) | 8/1/2022 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | x | Replace missing Up Thrust on top landing hall door | 6/28/2022 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Car shall have functioning Normal Terminal Limits actuating before Final Terminal Limit. | 8/1/2022 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. (Oil and rags in Pit) | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | Where pressure piping, valves, and cylinders use packing glands or seals, they shall be examined and maintained to prevent excessive loss of fluid. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency Phone in car fails to establish two-way communication |