Inspection
Inspection Details
Equipment ID
5154
5154
Inspection Date
7/23/2018
7/23/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
Phillip Moise, Jr.
Phillip Moise, Jr.
Relief Valve Pressure
340
340
Slide
Governor Rope Pull
Door Closing Force
28F/26R
28F/26R
External ID
f67ce318-d717-4a1f-bfdc-4cff02d1d923
f67ce318-d717-4a1f-bfdc-4cff02d1d923
Location
Maplewood High School
7539 MANCHESTER RD, MAPLEWOOD, MO
7539 MANCHESTER RD, MAPLEWOOD, MO
Owner
Attn: Audrey Hamilton
Maplewood Richmond Hts School Dist
7539 MANCHESTER RD, Maplewood, MO 63143
Phone: (314) 446-1711
Email: audrey.hamilton@mrhschools.net
Maplewood Richmond Hts School Dist
7539 MANCHESTER RD, Maplewood, MO 63143
Phone: (314) 446-1711
Email: audrey.hamilton@mrhschools.net
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Emergency phone and light not working | 7/23/2018 |
| conversion | conversion | n/a | No | No | Repair drop ceiling panels | 10/14/2025 |
| conversion | conversion | n/a | No | No | Door open button opens door when elevator goes into floor on Phase I | 10/14/2025 |
| conversion | conversion | n/a | No | No | Cam does not hit final limit | 10/14/2025 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | No | No | The fire extinguisher in the machine room is expired. A current test, ABC type fire extinguisher shall be provided in the elevator machine room. | 10/14/2025 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 10/14/2025 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | The cab lighting shall be guarded. | 10/14/2025 |
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 1001.2(a)(12) | No | No | Replace the missing ceiling panel. | 10/14/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | Electric eye is not working. | 1/31/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/14/2025 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | No | No | Fire service testing must be properly documented monthly on log sheet. | 10/14/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/14/2025 |