Inspection
Inspection Details
Equipment ID
21669
21669
Inspection Date
6/6/2022
6/6/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gregory Sacks
Gregory Sacks
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
370
370
Slide
Governor Rope Pull
Door Closing Force
NA
NA
External ID
c60579df-c604-4aef-87eb-0ecab2b325b6
c60579df-c604-4aef-87eb-0ecab2b325b6
Location
Storage of America
4327 GUSTINE AVE, SAINT LOUIS, MO
Phone: (314) 498-9800
4327 GUSTINE AVE, SAINT LOUIS, MO
Phone: (314) 498-9800
Owner
Attn: Tom Fitzpatrick
Storage of America
4327 Gustine, St. Louis, MO 63116
Phone: (314) 498-9800
Email: tfitzpatrick@storageofamerica.com
Storage of America
4327 Gustine, St. Louis, MO 63116
Phone: (314) 498-9800
Email: tfitzpatrick@storageofamerica.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)1 | No | No | The space between the solid cab wall of the elevator to the top of the elevator shall be enclosed with a non-combustible solid material or non-combustible lattice work with holes that will reject a ball 1.5 inches in diameter. | 9/18/2018 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean and dry. | 7/22/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | In car light switch shall be fixed. | 7/22/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | In car alarm bell shall work. | 6/23/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Lobby & 3rd floor hall call shall work. | 7/22/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lighting shall be operational. | 7/22/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit lighting shall be operational. | 7/22/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | Yes | The in car emergency alarm and emergency lighting shall be operational. - Unit Red Tagged for inoperative emergency services. | 4/22/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Only the relief valve pressure test was able to be performed. Could not get unit running. The rest of the category 1 annual inspection shall be completed. | 9/3/2021 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | No | No | Each freight enclosure shall have a capacity plate. loading class plates, and a "No Passengers" sign conspicuously posted. Letters shall not be less than one half inch (1/2") high. | 9/24/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | 1st floor rear door and 2nd floor both doors have non-wire glass in the vision panels and shall be replaced. | 9/24/2021 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | No | No | The cab lights shall be guarded. | 9/24/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | No | No | Means to access the hoistway shall be in a locked box. | 9/24/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | A seam in the cab wall is damaged and requires repair. | 9/24/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | The hoistway door chains are not properly attached on 1st floor rear door and both doors on the 3rd floor. Take corrective action. | 9/24/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)5 | No | No | Hoistway door pull straps are required on the inside and outside of all doors. | 9/24/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 9/24/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | RECOMMENDATIONS - NOT VIOLATIONS: It is strongly recommended that the hoistway doors should have the rigid astragals replaced with non-shearing astragals. It is also recommended to paint the bottom hoistway door panel floor stops and the area underneath the door stops a contrasting color. | 9/24/2021 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | Yes | No | Each freight enclosure shall have a capacity plate. loading class plates, and a "No Passengers" sign conspicuously posted. Letters shall not be less than one half inch (1/2") high. (2nd Notice - Re-Inspection Required) | 6/16/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | No | 110.7 - 1st floor rear door and 2nd floor both doors have non-wire glass in the vision panels and shall be replaced. (2nd Notice - Re-Inspection Required) | 6/16/2023 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | Yes | No | The cab lights shall be guarded. (2nd Notice - Re-Inspection Required) | 6/16/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | Yes | No | Means to access the hoistway shall be in a locked box. (2nd Notice - Re-Inspection Required) | 6/16/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Yes | No | A seam in the cab wall is damaged and requires repair. (2nd Notice - Re-Inspection Required) | 6/16/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Yes | No | The hoistway door chains are not properly attached on 1st floor rear door and both doors on the 3rd floor. Take corrective action. (2nd Notice - Re-Inspection Required) | 6/16/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)5 | Yes | No | Hoistway door pull straps are required on the inside and outside of all doors. (2nd Notice - Re-Inspection Required) | 6/16/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/20/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean and dry. | 10/20/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)10 | Yes | No | Pull chain boxes at top and bottom floors, must be lockable with a key and kept closed at all times, except when working on elevator. | 12/29/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)5 | Yes | No | Front hoistway doors on bottom floor needs a pull strap installed. | 12/29/2025 |