Inspection
Inspection Details
Equipment ID
5167
5167
Inspection Date
8/16/2018
8/16/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Clyde Johnson
Clyde Johnson
Mechanic Name
James Stabler
James Stabler
Relief Valve Pressure
700
700
Slide
Governor Rope Pull
NA
NA
Door Closing Force
25/24
25/24
External ID
50464fb4-7457-44df-b7c7-9ab45b607775
50464fb4-7457-44df-b7c7-9ab45b607775
Location
Jennings Jr High
8831 COZENS AVE, JENNINGS, MO
8831 COZENS AVE, JENNINGS, MO
Owner
Jennings School District
2559 DORWOOD DR, JENNINGS, MO 63136-4035
2559 DORWOOD DR, JENNINGS, MO 63136-4035
Billing
Attn: Jennings School District Facilities Dept
2541 DORWOOD DR, JENNINGS, MO 63136-4035
2541 DORWOOD DR, JENNINGS, MO 63136-4035
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The emergency car lighting is not operational, likely indicating that the back-up power device (battery) has failed. The fixture shall be repaired to operate. Reinspection required. | 2/24/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | The battery back–up lowering device was tested and did not operate as designed, the elevator failed to return to a lower floor and open its doors. Repair the device to operate as it is designed. | 5/20/2026 |
| A17.1-1996 : Elevators | 3.2 - Car top light and outlet | 1001.2(c)(2) | No | No | The car top inspection light/fixture did not operate. Repair fixture/light for proper operation and illumination for maintenance/emergency personnel. | 5/20/2026 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1004.2(a)(6) (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The elevator ADA telephone inside the elevator is not working properly. Check and repair the phone line of this phone for proper operation and passenger safety. Reinspection required. | 2/24/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency car lighting is not operational, likely indicating that the back-up power device (battery) has failed, needs repaired. Re-inspection required | 8/3/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | The car top inspection light fixture did not operate, repair for proper operation and illumination for maintenance / emergency personnel. | 5/20/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | The elevator ADA phone inside the elevator is not working, needs repaired. Re-inspection required | 8/3/2023 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone inside the elevator cab is not working. Re-inspection required | 8/3/2023 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is still not working. Re-inspection required | 12/6/2024 |