Inspection
Inspection Details
Equipment ID
20789
20789
Inspection Date
6/21/2022
6/21/2022
Inspection Type
Reinspection
Reinspection
Inspector Name
Sean Carmody
Sean Carmody
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
c4c82706-cea1-4688-a337-bd03769d5777
c4c82706-cea1-4688-a337-bd03769d5777
Location
St. Louis University High School
4970 Oakland Ave, St. Louis, MO
Phone: (314) 531-0330
4970 Oakland Ave, St. Louis, MO
Phone: (314) 531-0330
Owner
Attn: St. Louis University High School
St. Louis University High School
4970 Oakland Ave, St. Louis, MO 63110
Phone: (314) 531-0330
Email: mfischer@sluh.org
St. Louis University High School
4970 Oakland Ave, St. Louis, MO 63110
Phone: (314) 531-0330
Email: mfischer@sluh.org
Billing
Attn: St. Louis University High School
St. Louis University High School
4970 Oakland Ave, St. Louis, MO 63110
Phone: (314) 531-0330
Email: jrankin@siuh.org
St. Louis University High School
4970 Oakland Ave, St. Louis, MO 63110
Phone: (314) 531-0330
Email: jrankin@siuh.org
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 2.14.7.1.3 Provide Auxiliary Lighting | Yes | No | Make emergency light operational. | 7/29/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 7/29/2019 |
| A17.1-2016 : Elevators | 9.19 - Maintenance Records | 8.6.1.2.1(a) | No | No | Wiring prints and maintenance logs shall be kept on-site. | 5/27/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 5/27/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.12 - Controller Wiring, Fuses, Grounding, Etc. | 8.11.2.1.2(l) | No | No | Up-to-date wiring diagrams shall be provided on-site. | 5/27/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 8.11.2.1.1(q) | Yes | No | Emergency lowering device shall be operational. | 6/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | No wiring diagram in the machine room. | 5/27/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 5/27/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | 2-WAY COMMUNICATION DEVICE SHALL WORK. No Answer. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.2 - Hoistway doors | 2.12.7 | Yes | No | Hoistway Door Safety Retainers/Fire tabs shall be installed at the bottom of all hoistway doors. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | State Operating Permit shall be obtained and displayed in the Equipment Room. (EXPIRED: 6/21/2020) | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters Emergency Operation: Monthly Testing | No | No | Fire Service must be tested and properly documented monthly on Log Sheet. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Up-to-date wiring diagrams shall be provided on-site | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 2.20 | No | No | Suspension Rope Guards on hoist machine are missing Reinstall and adjust for proper clearance. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.15 - sign and operating device symbols | 2.26.12 | No | No | Replace missing Phase 1 instruction signage at Recall Floor. |