Inspection
Inspection Details
Equipment ID
13221
13221
Inspection Date
9/5/2018
9/5/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Ronald Edwards
Ronald Edwards
Mechanic Name
Daniel Novak
Daniel Novak
Relief Valve Pressure
580
580
Slide
Governor Rope Pull
Door Closing Force
F-15 / R-15
F-15 / R-15
External ID
9b05d385-54b7-4c9b-883f-794e8191547c
9b05d385-54b7-4c9b-883f-794e8191547c
Location
Rosewood
1415 W WHITE OAK ST, INDEPENDENCE, MO
1415 W WHITE OAK ST, INDEPENDENCE, MO
Owner
The Groves
1515 W WHITE OAK ST, INDEPENDENCE, MO 64050-2557
1515 W WHITE OAK ST, INDEPENDENCE, MO 64050-2557
Billing
Attn: The Groves
1515 W WHITE OAK ST, INDEPENDENCE, MO 64050-2557
1515 W WHITE OAK ST, INDEPENDENCE, MO 64050-2557
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.2.1 Phase 1 Emergency Recall OperationBy Fire Alarm initiating Devices | Yes | Yes | Bldg fire alarm panel being repaired | 12/23/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 (Re-Inspection) | No | No | No shunt trip disconnects in machroom where sprinkler is located | 12/23/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emg. phone not working | 12/17/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | door restrictor not working | 12/17/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | door restrictor not working front or rear | 12/3/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | pit need to be cleaned | 12/3/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | pit needs to be cleaned | 5/23/2023 |
| A17.1-2016 : Elevators | 1.15 - sign and operating device symbols | 8.6.1.6.7 | No | No | need to replace fire serv bezel in hall station | 10/28/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | no current cirt on display | 10/28/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | no current cirt displayed | 10/28/2024 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | phone not working no dial tone | 3/12/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | door open button not working | 10/28/2024 |