Inspection
Inspection Details
Equipment ID
564
564
Inspection Date
9/4/2018
9/4/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Joseph Ammons
Joseph Ammons
Relief Valve Pressure
Slide
Governor Rope Pull
n/a
n/a
Door Closing Force
25
25
External ID
4431d3da-9386-4b0c-a61d-cec1837bc8ef
4431d3da-9386-4b0c-a61d-cec1837bc8ef
Location
Callaway Nuclear Power Plant
PO BOX 620, FULTON, MO
PO BOX 620, FULTON, MO
Owner
AmerenUE- Fulton
PO BOX 620, FULTON, MO 65251-0620
PO BOX 620, FULTON, MO 65251-0620
Billing
Attn: AmerenUE- Callaway Plant
PO BOX 620, FULTON, MO 65251-0620
PO BOX 620, FULTON, MO 65251-0620
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Emergency light needs repaired | 11/8/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | 1.5 emergency light needs battery | 9/9/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | cab light needs cover for protection | 9/9/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | emergency light needs battery | 9/9/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency lights not working | 9/29/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.11 Runby (Re-Inspection) | Yes | No | Ropes need to be shortenee | 9/29/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Need Phase I and Phase II Fire service instructions placed by each key switch | 9/29/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.11 Runby (Re-Inspection) | Yes | No | Hoist ropes need to be shortened to provide minimum 6" runby clearance at counterweight buffer. | 9/17/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | phase 2 sign in cab missing | 9/25/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.2 Replacement of Suspension Means (Re-Inspection) | Yes | No | car is roped 2-1 with the cwt sheave having 1 of 4 rope grooves damaged by tension. needs to undercut or replace | 9/25/2025 |