Inspection
Inspection Details
Equipment ID
11252
11252
Inspection Date
3/21/2022
3/21/2022
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Jeffrey Borgeson
Jeffrey Borgeson
Relief Valve Pressure
490
490
Slide
Governor Rope Pull
Door Closing Force
21
21
External ID
359045a7-8413-42a0-b18b-97217ecb0771
359045a7-8413-42a0-b18b-97217ecb0771
Location
Vintage Gardens
3310 N WOODBINE RD, SAINT JOSEPH, MO
Phone: (816) 279-0774
3310 N WOODBINE RD, SAINT JOSEPH, MO
Phone: (816) 279-0774
Owner
Attn: Vintage Gardens
Vintage Gardens
3310 N Woodbine Rd, St. Joseph, MO 64505
Phone: (816) 279-3330 Ext: 10
Email: dmcgary@capitalseniorliving.net
Vintage Gardens
3310 N Woodbine Rd, St. Joseph, MO 64505
Phone: (816) 279-3330 Ext: 10
Email: dmcgary@capitalseniorliving.net
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.2-211.8 | Yes | Yes | Fire service hat lens on car operating panel has been knocked out and is missing. | 8/19/2020 |
| A17.1-1996 : Elevators | 1.15 - sign and operating device symbols | 1001.2(a)(15) | No | No | Need to identify unmarked floor lockout keyswitch located on car operating panel. | 8/26/2020 |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3d | No | No | Elevator machine room door needs to be self locking. | 8/26/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | Door unlocking rollers are missing on 1st and 2nd floor hoistway doors. | 8/19/2020 |
| A17.1-1996 : Elevators | 1.15 - sign and operating device symbols | 1001.2(a)(15) | No | No | Need to identify floor lockout keyswitch on car operating panel to corresponding car call that it locks out. | 8/26/2020 |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3d | No | No | Machine room door needs to be non-defeatable and self locking. | 8/26/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Replace missing hoistway door unlocking rollers on first and second floor. | 3/1/2021 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(a)(1) | No | No | No documentation of maintenance or testing in on site maintenance record log. | 7/15/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(c)(5) | No | No | Written checkout procedure for overspeed valve not on site. Needs to be kept in machine room. | 7/15/2022 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Test and log firefighter operation monthly | 7/15/2022 |
| A17.1-1996 : Elevators | 3.22 - Wire rope fastening and hitch plate | 212 | No | No | INSTALL LOCK NUTS ON DEAD END OF CABLES IN HOISTWAY OVERHEAD | 7/16/2025 |