Inspection
Inspection Details
Equipment ID
5328
5328
Inspection Date
6/25/2018
6/25/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Relief Valve Pressure
820
820
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
1bff2f3b-798f-485d-895d-b96968434f2d
1bff2f3b-798f-485d-895d-b96968434f2d
Location
Public Storage 07012
9030 WATSON RD, SAINT LOUIS, MO
9030 WATSON RD, SAINT LOUIS, MO
Owner
Public Storage Attn: Central Facilities
2200 K AVE STE 200, PLANO, TX 75074-5970
2200 K AVE STE 200, PLANO, TX 75074-5970
Billing
Attn: Public Storage Attn: Central Facilities
2200 K AVE STE 200, PLANO, TX 75074-5970
2200 K AVE STE 200, PLANO, TX 75074-5970
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room, | 4/9/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perfomr monthly fire service testing and document on log in machine room | 4/9/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Expired | 4/9/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Not up to date. Needs ‘22 docs | 4/9/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Expired | 4/9/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Not working correctly. | 4/13/2022 |
| MO Minimum : Elevators | 2.3 - Lighting and receptacles | 110.27 Guarding of Live Parts NFPA 72 | No | No | Machine room bulbs unguarded, repair as needed. | 4/9/2026 |
| MO Minimum : Elevators | 2.3 - Lighting and receptacles | 110.27 Guarding of Live Parts NFPA 72 | No | No | Machine room bulbs unguarded, repair as needed. | 4/9/2026 |
| MO Minimum : Elevators | 2.3 - Lighting and receptacles | 110.27 Guarding of Live Parts NFPA 72 | No | No | Car has egg crate type ceiling, provide guard on bulbs. | 4/9/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current copy of the state operating certificate shall be displayed in the machine room | 4/9/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Car has egg crate type ceiling. Provide guards on bulbs inside cab | 4/9/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Install guards on lights in machine room to protect from breakage | 4/9/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher has expired, needs service or replaced | 4/9/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Install code data plate with date & code elevator should be tested under. Re-inspection required | 4/9/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Place current state operating certificate in elevator machine room | 4/9/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 4/9/2026 |