Inspection
Inspection Details
Equipment ID
1971
1971
Inspection Date
8/23/2018
8/23/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Russell Bailey
Russell Bailey
Relief Valve Pressure
360
360
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
3dd56886-e011-4bde-936a-97a0bdb3c03b
3dd56886-e011-4bde-936a-97a0bdb3c03b
Location
Cox Medical Center North
1423 N JEFFERSON AVE, SPRINGFIELD, MO
1423 N JEFFERSON AVE, SPRINGFIELD, MO
Owner
Cox Medical Center
3801 S NATIONAL AVE, SPRINGFIELD, MO 65807-5210
3801 S NATIONAL AVE, SPRINGFIELD, MO 65807-5210
Billing
Attn: Cox Health Systems
1423 N JEFFERSON AVE, SPRINGFIELD, MO 65802-1917
1423 N JEFFERSON AVE, SPRINGFIELD, MO 65802-1917
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | needs new telephone | 1/8/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | 1.18.1: Car Door restrictor shall work. (REINSPECTION REQUIRED) | 7/27/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | Replace faded Phase 1 sighage and missing Phase 2 signage | 10/2/2020 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | S(1) Car call lockout switches not bypassed during fire service. (REINSPECTION REQUIRED) | 7/27/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | repair door restrictor | 3/7/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | Cab lighting used to power electronic door edge | 3/7/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated certificate | 3/1/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated Certificate | 11/27/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated one | 11/27/2023 |
| A17.1-2016 : Elevators | 1.15 - sign and operating device symbols | 8.6.1.6.7 | No | No | Must replace missing Door Close Braille in Car station 8.6.1.6.7 | 1/4/2026 |
| A17.1-2016 : Elevators | 1.15 - sign and operating device symbols | 8.6.1.6.7 | No | No | Must Replace missing "In Case Of Fire do not use Elevator" Sign at first floor landing. 8.6.1.6.7 | 1/4/2026 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Car Emergency System (Re-Inspection) | Yes | No | must make emergency light operable. 8.6.4.15 | 1/4/2026 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Must make Emergency alarm operable. 8.6.4.15 | 1/4/2026 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Must make emergency phone operable. 8.6.4.15 |