Inspection
Inspection Details
Equipment ID
3438
3438
Inspection Date
7/22/2022
7/22/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Bryan Henson
Bryan Henson
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
5bb593e7-632b-4523-9807-ce02080709e2
5bb593e7-632b-4523-9807-ce02080709e2
Location
JC Penney- Joplin # 1339-1
101 Range Line Rd, Joplin, MO
Phone: (417) 623-5700
Alt Phone: (972) 431-1612
Email: svance3@contractor.jcp.com
101 Range Line Rd, Joplin, MO
Phone: (417) 623-5700
Alt Phone: (972) 431-1612
Email: svance3@contractor.jcp.com
Owner
Attn: JC Penney- Joplin # 1339-1
JC Penney- Joplin # 1339-1
101 N Range Line Rd, Joplin, MO 64801
Phone: (214) 429-9416
Email: salvar83@jcp.com
JC Penney- Joplin # 1339-1
101 N Range Line Rd, Joplin, MO 64801
Phone: (214) 429-9416
Email: salvar83@jcp.com
Billing
Attn: Joseph Tyler
Penney OpCo., LLC
2401 S Stemmons Frwy, Unit 4000, Lewisville, TX 75067
Phone: (469) 352-7327
Email: jtyler15@jcp.com
Penney OpCo., LLC
2401 S Stemmons Frwy, Unit 4000, Lewisville, TX 75067
Phone: (469) 352-7327
Email: jtyler15@jcp.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | demarcation lights not working | 11/8/2019 |
| conversion | conversion | n/a | No | No | esculator needs clean down | 11/8/2019 |
| conversion | conversion | n/a | No | No | speed monitoring device does not work did not shut down or sound alarm | 11/8/2019 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2 | No | No | 8.10.4.1.1(e)(2) demarcation lighting not working | 11/8/2019 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | Left hand rail needs replaced 30 days | 12/3/2021 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.3 Step/Skirt Performance Index | Yes | No | No step index testing data given to Inspector at time of Inspection ( Step Gap, Friction, Graph Data, etc). | 1/9/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | 8.1.2: Escalator machine spaces(pits) shall be kept clean and free from excessive debris, (Dirt, Dust, oil, etc) ( | 1/25/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Unit needs full clean down. | 1/25/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Unit needs annual clean down | 6/7/2024 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5.2(i) Demarcation lighting | Yes | No | Provide operational demarcation lights | 4/23/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Preform annual clean down | 6/7/2024 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5.2(i) Demarcation lighting | Yes | No | provide operational demarcation lights | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | perform annual clean down | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | provide undamaged hand rail |