Inspection
Inspection Details
Equipment ID
8681
8681
Inspection Date
7/17/2018
7/17/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
480
480
Slide
Governor Rope Pull
Door Closing Force
15
15
External ID
8e6b32b0-fda5-4245-93c8-a3d6267d0a0c
8e6b32b0-fda5-4245-93c8-a3d6267d0a0c
Location
Cambridge Court Condos
922 CLAYTONBROOK DR, BALLWIN, MO
922 CLAYTONBROOK DR, BALLWIN, MO
Owner
Baumann Property Co
217 CLARKSON EXECUTIVE PARK, ELLISVILLE, MO 63011-2173
217 CLARKSON EXECUTIVE PARK, ELLISVILLE, MO 63011-2173
Billing
Attn: Baumann Property Company
217 CLARKSON EXECUTIVE PARK, ELLISVILLE, MO 63011-2173
217 CLARKSON EXECUTIVE PARK, ELLISVILLE, MO 63011-2173
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (I) - Pits | (I)1 | Remove the fluids from the pit and determine the source of the leak and repair. | |||
| MO Minimum : Elevators | (I) - Pits | (I)1 | The elevator pit shall be kept clean and dry. | |||
| MO Minimum : Elevators | (I) - Pits | (I)1 | The pit shall be kept clean and dry. Remove the water from the pit. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | x | Per the MO AHJ, this elevator has been confirmed to have a single bottom jack. The jack shall be replaced or have a governor with safeties installed or a plunger gripper installed. If the jack is replaced, documentation shall be available on-site at all time and shall be provided to the state. | 9/6/2023 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | The in car emergency light shall be operational. | 9/6/2023 | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | x | All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. Pit has 4 to 6 inches of water in it. | 9/6/2023 | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | x | Remove fluids from the pit and determine source of the leak and repair. This violation has been cited 4 years in a row. | 8/6/2024 | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | x | Remove rust from pit equipment. Repair/replace as needed and apply rust prevention treatment to all pit steel. Pit shall be kept dry, investigate/repair source of leak. | 8/6/2024 | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display a copy of the current state operating certificate in the machine room. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | x | Door operator close limit not working properly. Repair/replace as needed. | 8/6/2024 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | x | Detector edge shall work with car lighting off. NEC prohibits safety devices being on lighting circuit. | 8/6/2024 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | [2:56 PM] jimsacks superiorelevatorinspections.com Compliant/Required documentation shall be kept in the equipment room (neat/organized) including MCP, wiring diagrams, PM log, callback log, oil log, and evacuation procedures. Fire service log to be recorded monthly. | |||
| MO Minimum : Elevators | (I) - Pits | (I)1 | x | Remove the fluids from the pit and determine the source of the leak and repair. All violations are repeat violations from previous years and the AHJ requires that all violations must be re-inspected. | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | x | Remove rust from pit equipment, repair/replace as needed, apply rust prevention treatment to all pit steel. Pit shall be kept dry, investigate/repair water leak. All violations are repeat violations from previous years and the AHJ requires that all violations must be re-inspected. | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | x | Detector edge shall work with cab lighting off. NEC prohibits safety devices being on lighting circuit. All violations are repeat violations from previous years and the AHJ requires that all violations must be re-inspected. | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | x | Compliant/required documentation & MCP shall be kept in equipment room (neat/organized and not on car top) including wiring diagrams, oil log, and fire service log, recorded monthly. All violations are repeat violations from previous years and the AHJ requires that all violations must be re-inspected. | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | x | Machine room door shall be self-closing and self-locking. | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | This unit is equipped with an overspeed valve and is due for category 5 testing on or before the next annual inspection. |