Inspection
Inspection Details
Equipment ID
24190
24190
Inspection Date
1/1/2018
1/1/2018
Inspection Type
Reinspection
Reinspection
Inspector Name
Matthew Goff
Matthew Goff
Mechanic Name
Relief Valve Pressure
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
OK
OK
External ID
ac758797-6966-43b9-81d3-43155c870cb8
ac758797-6966-43b9-81d3-43155c870cb8
Location
The Preserve
6331 N KLAMM RD BLDG 6, KANSAS CITY, MO
6331 N KLAMM RD BLDG 6, KANSAS CITY, MO
Owner
Altitude 970
6301 N KLAMM RD, KANSAS CITY, MO 64151-2436
6301 N KLAMM RD, KANSAS CITY, MO 64151-2436
Billing
Attn: Altitude 970
6301 N KLAMM RD, KANSAS CITY, MO 64151-2436
6301 N KLAMM RD, KANSAS CITY, MO 64151-2436
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | The 110V car light disconnecting means in the electrical room at "*2" shall be capable of being locked in the open position | |
| conversion | conversion | n/a | No | No | Elevator released for temporary use until 2-12-2018. Correct / Address all deficiencies and schedule an inspection by 2-12-2018 | |
| conversion | conversion | n/a | No | No | Sure-up electrical in the electrical room at "*2" | |
| conversion | conversion | n/a | No | No | The crosshead data plate shall be legible | |
| conversion | conversion | n/a | No | No | Secure the counterweights in the counterweight frame | |
| conversion | conversion | n/a | No | No | The minimum car runby shall be 6 inches | |
| conversion | conversion | n/a | No | No | Provide working Schindler's PEBO and test | |
| conversion | conversion | n/a | No | No | Schindler's data plate in pit. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.27 - Crosshead data plate | 8.11.2.1.3(k) | No | No | The crosshead data plate shall be legible per | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.28 - Counterweight and counterweight buffer | 8.11.2.1.3(m) | No | No | Secure the counterweights in the counterweight frame | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.11.2.1.1(e) Car Lighting | No | No | The 110V car light disconnecting means in the electrical room at "*2" shall be capable of being locked in the open position | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 8.11.2.1.5(b) | Yes | Yes | The minimum car runby shall be 6 inches |