Inspection
Inspection Details
Equipment ID
6736
6736
Inspection Date
8/24/2022
8/24/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Brant Willtrout
Brant Willtrout
Relief Valve Pressure
480
480
Slide
Governor Rope Pull
Door Closing Force
19
19
External ID
5d964257-cbbc-49df-be3d-2f435bd06e0a
5d964257-cbbc-49df-be3d-2f435bd06e0a
Location
Inn Town Suites
9067 Dunn Rd, Hazelwood, MO
Phone: (314) 731-1902
9067 Dunn Rd, Hazelwood, MO
Phone: (314) 731-1902
Owner
Attn: Tammy Church
In Town Suites-St. Charles
980 Hammond Dr, Ste 500, Atlanta, GA 30328
Phone: (770) 799-5239
Email: Tammy.Church@intownsuites.com
In Town Suites-St. Charles
980 Hammond Dr, Ste 500, Atlanta, GA 30328
Phone: (770) 799-5239
Email: Tammy.Church@intownsuites.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Correct cab clearance in hoistway | 1/13/2020 |
| conversion | conversion | n/a | No | No | Trim cab flooring - trip hazard | 1/13/2020 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service test & document on log posted in machine room, | 3/25/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | Provide Phase 1 Fire Service instructions at the 1st floor & phase 2 fire service instructions in the car | 3/25/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove all non elevator storage from machine room | 3/25/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Need testing procedures in the MCP on or before 1/1/22 | 10/26/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | No | No | Provide Phase 1 Fire Service instructions at the 1st Floor, Provide Phase 2 Fire Service instructions in car | 11/5/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 11/5/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean Pit | 11/5/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Repair pit light | 11/5/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Provide lock for machine room access door | 11/5/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | 11/5/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Repair pit lighting repeat violation | 11/5/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Post phase 1 & 2 fire service instructions at 1st floor & in the car | 11/5/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 11/5/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 11/5/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 11/5/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove all non elevator storage from the machine room | 11/5/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove trash from the pit and excess lint from the rails | 11/5/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Provide contact protection for the elevator cab lighting to prevent the glass from falling in the elevator | 12/10/2025 |