Inspection
Inspection Details
Equipment ID
21311
21311
Inspection Date
8/21/2018
8/21/2018
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
William Gorden, Jr.
William Gorden, Jr.
Relief Valve Pressure
Slide
Type A
Type A
Governor Rope Pull
40/380
40/380
Door Closing Force
23
23
External ID
492aa458-465e-4ac4-9927-d1bc4d73644e
492aa458-465e-4ac4-9927-d1bc4d73644e
Location
Gotham Aparments
5904 ENRIGHT AVE, SAINT LOUIS, MO
5904 ENRIGHT AVE, SAINT LOUIS, MO
Owner
The Gotham Buildings, LLC
5904 ENRIGHT AVE, SAINT LOUIS, MO 63112-2060
5904 ENRIGHT AVE, SAINT LOUIS, MO 63112-2060
Billing
Attn: The Gotham Buildings, LLC
6014 DELMAR BLVD, SAINT LOUIS, MO 63112-1423
6014 DELMAR BLVD, SAINT LOUIS, MO 63112-1423
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | Phase II fire service does not work, doors will not close. Did not red tag - Repair by 2-9-20 | 8/27/2020 |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Phone in elevator cab does not work. | 8/27/2020 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Provide maintenance control program. | 9/24/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | Clean pit. | 9/24/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.9 Cleaning of Car Tops | Clean car top. | 9/24/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 8.11.2.1.2(d) | Remove all non-elevator related equipment from machine room. | 9/24/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | Provide guards on lights to prevent accidental contact or breakage. | 9/24/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Provide correct type of (ABC) fire extinguisher in elevator machine room. | 9/24/2020 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not work on 110v emergency power or normal power | 6/29/2022 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Fire extinguisher is out of date and must be serviced. | 12/16/2021 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone is not working. RE-inspection required | 11/23/2022 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.11 Runby (Re-Inspection) | x | Only 3 inches of C measurement, needs shortening. Re-inspection required | 2/16/2024 |