Inspection
Inspection Details
Equipment ID
9795
9795
Inspection Date
9/6/2022
9/6/2022
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Aaron Bagley
Aaron Bagley
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
6aebf7cc-dc7d-4507-991d-d345352aa3c7
6aebf7cc-dc7d-4507-991d-d345352aa3c7
Location
The Dome
901 N Broadway, St. Louis, MO
Phone: (314) 342-5094
901 N Broadway, St. Louis, MO
Phone: (314) 342-5094
Owner
Attn: America's Center
America's Center
701 Convention Plz, St. Louis, MO 63101
Phone: (314) 342-5118
Email: mgruhala@explorestlouis.com
America's Center
701 Convention Plz, St. Louis, MO 63101
Phone: (314) 342-5118
Email: mgruhala@explorestlouis.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Provide written maintenance control program to include wiring diagrams to be kept on site. | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Perform unit clean down and repair seals causing oil leak on steps. | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(E) | No | No | Top right comb plate has 2 missing teeth, needs replaced | 6/4/2026 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current certificate | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.11.4.2.13 Escalator Handrail Safety Systems | Yes | No | Provide Category 1 testing.of handrail | 9/20/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.3 Step/Skirt Performance Index | Yes | No | Provide Category 1 testing.of step/ skirt index | 9/20/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(A) | Yes | No | Provide Category 1 testing.of brake torque. | 9/20/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.4 Escalator Combplates | Yes | No | Provide Category 1 testing, lower center comb. | 9/20/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.14 Escalator Entrance and Egress Ends | Yes | Yes | Screws broken off upper center comb plate during testing, unit removed from service. | 9/20/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Perform complete clean down to remove oil leaking from drive machine. | 6/4/2026 |
| MO Minimum : Elevators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | T(1) 704 Driving Machines and Sheaves | No | No | Need to replace leaking seal on drive machine. | 6/4/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(F) | No | No | Repair balustrade joint on right side to match up with adjacent panel | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Unable to test brake torque because testing point is stripped. Repair or replace and re-inspect within 60 days | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current certificate | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Perform complete clean down to remove oil leaking from drive machine. | |
| MO Minimum : Elevators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | T(1) 704 Driving Machines and Sheaves | No | No | Need to replace leaking seal on drive machine. |